Aortic Dilatation on the Edge of Dissection—Do We Operate Too Late? The Ratio between Ascending and Descending Aorta DiameteR (RADAR)
Rattachement africain : ch. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
(1) Background: There is a need for a novel surrogate marker to ease decision making when facing ascending aortic dilatation. In this article, we study the ratio between ascending and descending aorta diameters as a potential one. (2) Methods: Retrospective observational cohort study, including all the patients who underwent surgery for acute type A aorta dissection (aTAAD) between January 2014 and September 2020 at our center. A total of 50 patients were included. Clinical and demographic data were collected. The anatomical measurements were made including orthogonal maximal diameters of the ascending and descending aorta, post-dissection whole circumference length (post-wCL), post-dissection true lumen circumference length (post-tCL), and surface and sphericity indices of the ascending and descending aorta. Pre-dissection ascending aorta diameter (pre-AAD) and pre-dissection descending aorta diameter (pre-DAD) were calculated as well as the ratio between them and compared with reference values. (3) Results: Of the pre-AAD patients, 96% had smaller than the recommended 55 mm. The ratio between the descending and ascending aorta pre-dissection diameters was significantly smaller compared to the reference value (0.657 ± 0.125 versus 0.745 ± 0.016 with a mean difference of −0.088 and a p < 0.001). (4) Conclusions: The 55 mm threshold for aorta maximal diameter is an insufficient criterion when assessing the risk of dissection. The ratio between DAD and AAD is a parameter worthy of analysis as a tool to stratify the risk of dissection.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Aortic Dilatation on the Edge of Dissection—Do We Operate Too Late? The Ratio between Ascending and Descending Aorta DiameteR (RADAR)
- Date Crossref
- 29/06/2023
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.