Aller au contenu principal
Accès ouvert déclaré 2023 article

Pressure resistance evaluation in esophagojejunostomy using the transorally inserted anvil (OrVilTM)

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : us, jp. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Aim: The transorally inserted anvil (OrVilTM) is often selected for esophagojejunostomy after total laparoscopic gastrectomy due to its versatility. During anastomosis with OrVilTM, it is possible to select a double stapling technique (DST) or a hemi-double technique (HDST) by overlapping the linear stapler and the circular stapler, although there has been no report on the anastomotic strength. Thus, an animal experiment was conducted and verified this study. Methods: This experiment used 10 fresh porcine esophageal and jejunal specimens. Two models were created: a model in which the rod is placed at the center of the esophageal transection line (DST model) and a model in which the rod is placed at the lateral end of the esophageal transection line (HDST model). A pressure gage was inserted into the anastomosed intestine while continuously measuring pressure to determine the leakage site and leakage pressure. Results: The leakage site in both the DST (n = 5) and HDST models (n = 5) were at the staple overlapping with a leakage pressure of 151.2 ± 14.2 mmHg in the DST model and 148.2 ± 6.3 mmHg in the HDST model (P = 0.678). When the leakage site was repaired with hand-sewn sutures and conducted remeasuring pressure, leakage was observed from the contralateral crossing in the DST model and the leakage pressure was 155.8 ± 12.2 mmHg. In the HDST model, all models were capable of withstanding 300-mmHg pressures. Conclusion: HDST with a single staple intersection is beneficial for esophagojejunostomy, in terms of pressure resistance, and the repairing suture at the staple intersection can increase pressure resistance.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Pressure resistance evaluation in esophagojejunostomy using the transorally inserted anvil (OrVilTM)
Date Crossref
01/01/2023
Éditeur
OAE Publishing Inc.
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Esophageal and GI PathologyEsophageal Cancer Research and TreatmentMetastasis and carcinoma case studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.