MR‐zero meets RARE MRI: Joint optimization of refocusing flip angles and neural networks to minimize T2 ‐induced blurring in spin echo sequences
Rattachement africain : de. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Purpose An end‐to‐end differentiable 2D Bloch simulation is used to reduce T2 induced blurring in single‐shot turbo spin echo sequences, also called rapid imaging with refocused echoes (RARE) sequences, by using a joint optimization of refocusing flip angles and a convolutional neural network. Methods Simulation and optimization were performed in the MR‐zero framework. Variable flip angle train and DenseNet parameters were optimized jointly using the instantaneous transverse magnetization, available in our simulation, at a certain echo time, which serves as ideal blurring‐free target. Final optimized sequences were exported for in vivo measurements at a real system (3 T Siemens, PRISMA) using the Pulseq standard. Results The optimized RARE was able to successfully lower T2‐induced blurring for single‐shot RARE sequences in proton density‐weighted and T2‐weighted images. In addition to an increased sharpness, the neural network allowed correction of the contrast changes to match the theoretical transversal magnetization. The optimization found flip angle design strategies similar to existing literature, however, visual inspection of the images and evaluation of the respective point spread function demonstrated an improved performance. Conclusions This work demonstrates that when variable flip angles and a convolutional neural network are optimized jointly in an end‐to‐end approach, sequences with more efficient minimization of T2‐induced blurring can be found. This allows faster single‐ or multi‐shot RARE MRI with longer echo trains.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- <scp>MR‐zero</scp> meets <scp>RARE MRI:</scp> Joint optimization of refocusing flip angles and neural networks to minimize <scp>T<sub>2</sub></scp>‐induced blurring in spin echo sequences
- Date Crossref
- 25/06/2023
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.