Aller au contenu principal
Accès ouvert déclaré 2023 article

Stable Chitosan and Prussian Blue-Coated Laser-Induced Graphene Skin Sensor for the Electrochemical Detection of Hydrogen Peroxide in Sweat

50Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

High Resolution Image Download MS PowerPoint Slide Developing a noninvasive skin peroxide monitoring technology is highly desirable for managing a number of metabolic disorders associated with diabetes, pulmonary diseases, or other health conditions. To date, the majority of studies on peroxide detection have been conducted on simulated sweat and high pH conditions, which are beyond the physiological range, in order to provide an enhanced response. Here, a skin-worn amperometric sensor, based on laser-induced graphene (LIG), surface-engineered with a Prussian blue (PB)–chitosan (CS) network was fabricated by one-step electrodeposition for the stable and sensitive detection of H 2 O 2 in human eccrine perspiration. The hybrid (PB–CS) network and laser-written electrode configuration were optimized through systematic investigation of electrodeposition parameters and concurrent feedback from electrochemical and morphological characterization at each fabrication step. Different from the multitude of carbon-based electrodes functionalized with metallic nanoparticles reported in the literature, the sensor was operated at a low potential of −0.036 V vs Ag/AgCl in unmodified human eccrine perspiration. The low working potential ensured that the sensor is highly specific, immune to the current from oxygen reduction or common interfering species, whereas the inclusion of CS in the hybrid coating afforded a highly stable performance over a period of 14 days. The sensor was able to monitor H 2 O 2 over the linear range of 10–1000 μM with a low detection limit of 6.31 μM and achieved a recovery of 98.73% (%RSD 0.86) in human eccrine perspiration. This facile biosensor based on directly laser-written electrodes coupled with the one-step PB–CS fabrication strategy has the potential to form the basis for the development of oxidase enzyme-based sensors in sweat.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Stable Chitosan and Prussian Blue-Coated Laser-Induced Graphene Skin Sensor for the Electrochemical Detection of Hydrogen Peroxide in Sweat
Date Crossref
09/06/2023
Éditeur
American Chemical Society (ACS)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Electrochemical sensors and biosensorsAdvanced Sensor and Energy Harvesting MaterialsAnalytical Chemistry and Sensors

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.