Aller au contenu principal
Accès ouvert déclaré 2023 article

Research on Improved Quantitative Identification Algorithm in Odor Source Searching Based on Gas Sensor Array

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

In order to improve the precision of gas detection and develop valid search strategies, the improved quantitative identification algorithm in odor source searching was researched based on the gas sensor array. The gas sensor array was devised corresponding to the artificial olfactory system, and the one-to-one response mode to the measured gas was set up with its inherent cross-sensitive properties. The quantitative identification algorithms were researched, and the improved Back Propagation algorithm was proposed combining cuckoo algorithm and simulated annealing algorithm. The test results prove that using the improved algorithm to obtain the optimal solution -1 at the 424th iteration of the Schaffer function with 0% error. The gas detection system designed with MATLAB was used to obtain the detected gas concentration information, then the concentration change curve may be achieved. The results show that the gas sensor array can detect the concentration of alcohol and methane in the corresponding concentration detection range and show a good detection performance. The test plan was designed, and the test platform in a simulated environment in the laboratory was found. The concentration prediction of experimental data selected randomly was made by the neural network, and the evaluation indices were defined. The search algorithm and strategy were developed, and the experimental verification was carried out. It is testified that the zigzag searching stage with an initial angle of 45° is with fewer steps, faster searching speed, and a more exact position to discover the highest concentration point.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Research on Improved Quantitative Identification Algorithm in Odor Source Searching Based on Gas Sensor Array
Date Crossref
08/06/2023
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced Chemical Sensor TechnologiesInsect Pheromone Research and ControlGas Sensing Nanomaterials and Sensors

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.