Evaluation of the Vmaxpro sensor for assessing movement velocity and load-velocity variables: accuracy and implications for practical use
Rattachement africain : de, cn, fi. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
We investigated the ecological validity of an inertial measurement unit (IMU) (Vmaxpro) to assess the movement velocity (MV) during a 1-repetition maximum (1RM) test and for the prediction of load-velocity (L-V) variables, as well as the ecological intra-day and inter-day reliability during free-weight bench press (BP) and squat (SQ).Furthermore, we provide recommendations for the practical use of the sensor.Twenty-three strength-trained men completed an incremental 1RM test, whereas seventeen men further participated in another 3 sessions consisting of 3 repetitions with 4 different loads (30, 50, 70 and 90% of 1RM) to assess validity and intra-and inter-day reliability, respectively.The MV was assessed using the Vmaxpro and a 3D motion capture system (MoCap).L-V variables and the 1RM were calculated based on submaximal velocities.The Vmaxpro showed high validity during the 1RM test for BP (r = 0.935) and SQ (r = 0.900), but with decreasing validity at lower MVs.The L-V variables and the 1RM demonstrated high validity for BP (r = 0.808-0.942)and SQ (r = 0.615-0.741)with a systematic overestimation.Coefficients of variance for intra-and inter-day reliability ranged from 2.4% to 9.7% and from 3.2% to 8.6% for BP and SQ, respectively.The Vmaxpro appears valid at high and moderately valid at low MVs.Depending on the required degree of accuracy, the sensor may be sufficient for the prediction of L-V variables and the 1RM.Our data indicate the sensor to be suitable for monitoring changes in MVs within and between training sessions.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Evaluation of the Vmaxpro sensor for assessing movement velocity and load-velocity variables: accuracy and implications for practical use
- Date Crossref
- 01/01/2024
- Éditeur
- Termedia Sp. z.o.o.
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.