Ultrasound-guided Axillary Vein Puncture for Cardiac Device Implantation: A Safe and Effective Approach

13Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Ultrasound-guided axillary vein access is an effective alternative to conventional subclavian and cephalic access for cardiac implantable electronic device implantation.The aim of this study was to compare the safety, efficacy, and radiation exposure data of the ultrasound-guided axillary approach with other conventional access techniques.The study population included 130 consecutive patients, stratified as 65 (64% male; median age, 79 years) in the study group and 65 (66% male; median age, 81 years) in the control group.We performed a retrospective not-randomized analysis by comparing ultrasound-guided axillary vein puncture with subclavian and cephalic approaches in order to test the effect on X-ray exposure, total procedure time, and complications.Significant differences were observed in terms of radiation exposure, including fluoroscopy time (median, 95 s [study group] vs. 193 s [control group]; P < .001),air kerma (median, 29 mGy [study group] vs. 55.7 mGy [control group]; P < .001),and dose-area product (median, 8219 mGy • cm 2 [study group] vs. 16736 mGy • cm 2 [control group]; P < .001).The median procedure time was 45 min in the study group but 50 min in the control group (P < .05).Complications occurred in 6 control group patients (1 urticaria contrast medium-related, 3 pneumothorax, 2 subclavian artery puncture) and 2 study group patients (2 axillary artery puncture).We conclude that the ultrasound-guided axillary venous approach is a fast, feasible, and safe technique for cardiac lead implantation.It allows a significant reduction in fluoroscopy time without prolonging the procedural time.This approach offers direct visualization of the vessel during the puncture, so it can be useful in patients who cannot receive contrast medium, those who require "difficult" thoracic approaches (emphysema, too much or too little fat tissue), or those on anticoagulant therapy.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Ultrasound-guided Axillary Vein Puncture for Cardiac Device Implantation: A Safe and Effective Approach
Date Crossref
01/04/2023
Éditeur
MediaSphere Medical LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Central Venous Catheters and HemodialysisCardiac Arrhythmias and TreatmentsCardiac pacing and defibrillation studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.