The first decade of flow diversion for intracranial aneurysms with the Pipeline embolization device
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVE: Flow diverter devices have revolutionized the treatment of intracranial aneurysms (IAs) since their approval in 2011 and have continued to evolve. The devices have been widely adopted across institutions and centers over the past decade; however, long-term follow-up after treatment with the Pipeline embolization device (PED) is not well described in the literature. The authors' institution was among the first to begin using PEDs, allowing them to report their series of patients treated with flow diverters ≥ 10 years ago. In this study, the authors aimed to evaluate the long-term angiographic and clinical outcomes of these patients and review lessons learned along the way. METHODS: The authors performed a retrospective review of their institution's IA database from January 2007 to July 2012. All patients with IAs treated with a PED prior to July 2012 were included. Clinical and angiographic characteristics were extracted. Available angiographic follow-up at 1, 3, 5, and 10 years was reported. RESULTS: A total of 83 patients with 92 aneurysms treated with a PED ≥ 10 years ago were identified and included in the study. The mean aneurysm dome diameter was 9.2 (SD 5.7) mm, the mean aneurysm height was 10.4 (SD 6.8) mm, and the mean neck width was 4.1 (SD 2.4) mm. Only 1 (1.1%) aneurysm was ruptured at presentation. Eight (8.7%) aneurysms were recurrences of previous treatment modalities. The morphology was saccular in 77 (83.7%) aneurysms, fusiform in 14 (15.2%), and blister-like in 1 (1.1%). Among saccular aneurysms, 60 (77.9%) were wide-necked. Seventy-five (81.5%) aneurysms were in the internal carotid artery, 12 (13.0%) were vertebrobasilar, 3 (3.3%) were in the middle cerebral artery, and 2 (2.2%) were in the posterior cerebral artery. Angiographic follow-up at 1, 3, 5, and 10 years was available for 75, 59, 50, and 15 patients, respectively. The complete occlusion rates at 1, 3, 5, and 10 years were 94.7%, 96.6%, 96.0%, and 100%, respectively. The retreatment rates at 1, 3, 5, and 10 years were 8.0%, 6.8%, 8.0%, and 6.7%, respectively. CONCLUSIONS: The authors provide their single-institution series of IA patients treated with a PED ≥ 10 years ago, with the first report of 10-year follow-up for the available patients.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- The first decade of flow diversion for intracranial aneurysms with the Pipeline embolization device
- Date Crossref
- 01/05/2023
- Éditeur
- Journal of Neurosurgery Publishing Group (JNSPG)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Kaleida Health Department of Neurosurgery pays non établi dans la noticeÉtablissement de santé
-
Jacobs Institute pays non établi dans la noticeOrganisation à but non lucratif
-
Canon (United States) pays non établi dans la noticeEntreprise
-
University Radiology pays non établi dans la noticeUniversité ou école supérieure
-
Departments of Neurosurgery pays non établi dans la noticeInstitution
-
Jacobs School of Medicine and Biomedical Sciences pays non établi dans la noticeUniversité ou école supérieure
-
University at Buffalo Canon Stroke and Vascular Research Center pays non établi dans la noticeUniversité ou école supérieure
Department of Neurosurgery — Kaleida Health, Jacobs Institute et Canon (United States), avec 4 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.