Initial Clinical Experience with Thin-Film Polyimide Subdural Electrodes for Seizure Monitoring (P2-1.005)

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Objective: NA Background: Subdural grid-and-strips are used routinely in pre-surgical evaluations for people with drug-resistant epilepsy (DRE). Thin-film polyimide electrodes (NeuroOne Evo, 0.08mm) which have been approved for clinical use, are thinner and better conform to brain convolutions than current market grids. Design/Methods: We present two patients with DRE who underwent intracranial EEG (iEEG) monitoring with thin-film polyimide subdural electrode grid- and-strip electrodes as well as traditional EEG for pre-surgical evaluation. Patient 1 had a prior left mesial temporal lobe ablation with seizure recurrence. They underwent left temporal craniotomy with implantation of two subdural grids, three strips and additional depth electrodes. IEEG demonstrated two habitual seizures arising from anterior temporal subdural strips. Functional mapping identified the basal-temporal and Wernicke’s speech areas. Left anterior temporal lobectomy was performed and he remains seizure free 9 months post-resection. Patient 2 underwent bilateral stereoEEG electrode placement with coverage in the frontal/temporal/insular regions and subdural strip electrodes. IEEG demonstrated seizure onset from the left hippocampus and right hippocampal spikes. Given bilateral findings, they underwent Responsive Neurostimulation System implantation. Results: The two patients underwent subdural electrode placements without complications. IEEG recordings were comparable between NeuroOne Evo and traditional electrodes in terms of integrity, artifactual content and signal recording characteristics. The thinner profile of the Evo grid tail facilitated dura closure and reduced mass effect compared to traditional grids. By trimming material from the tip of the subdural strip, the electrode was placed through a burr hole without difficulty. Recording from these grids contributed to presurgical evaluation and led to surgical interventions. Conclusions: Our initial experience suggests that thin-film electrodes are a viable option for subdural iEEG that could safely minimize intracranial mass effect/brain shift and improve surgical ease of use. Disclosure: Dr. Reina has nothing to disclose. Dr. Song has received personal compensation in the range of $0-$499 for serving as a Consultant for Clearpoint Neuro. The institution of Dr. Song has received research support from NIH. Dr. Culler has nothing to disclose. Dr. Aronson has received personal compensation in the range of $500-$4,999 for serving as a Consultant for Medtronic.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Initial Clinical Experience with Thin-Film Polyimide Subdural Electrodes for Seizure Monitoring (P2-1.005)
Date Crossref
25/04/2023
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Epilepsy research and treatmentNeurological disorders and treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.