Aller au contenu principal
2023 article

Biologic and Mechanical Stability of Screw-Retained Layered Zirconia Crowns Bonded to CAD/CAM Titanium Abutments Using Angulated Screw Access: A Prospective Closed Cohort Study

3Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Michael R. Norton, BDS FDS RCS(Ed): Purpose: To evaluate hard and soft tissue response and mechanical integrity for screw-retained layered zirconia crowns bonded to titanium nitride–coated titanium (TiN) CAD/CAM abutments supported by implants at 1- and 2-year follow-ups. Materials and Methods: A total of 46 patients were restored with a total of 102 free-standing implant-supported layered zirconia crowns, which were bonded to their respective abutments in the dental laboratory and delivered as a one-piece screw-retained crown. Baseline, 1-year, and 2-year data were collated on pocket probing depth, bleeding on probing, marginal bone levels, and mechanical complications. Results: Of the 46 patients, 4 patients with one implant each were not followed-up. These patients were not included in the analysis. Of the remaining 98 implants, due to failed appointments during the global pandemic, soft tissue measurements were recorded for 94 implants at year 1 and 86 implants at year 2, with a mean buccal/lingual pocket probing depth of 1.80/1.95 mm and 2.09/2.17 mm, respectively. Mean bleeding on probing was 0.50 and 0.53 at 1 and 2 years, which represents somewhere between no bleeding and a spot bleed according to the study protocol. Radiographic data were available for 74 implants at year 1 and 86 implants at year 2. The mean marginal bone change from baseline was +0.11 mm mesially and +0.19 mm distally at 1 year and +0.24 mm mesially and +0.16 mm distally at 2 years. The final bone level with respect to the reference point was +0.49 mm mesially and +0.19 mm distally at the end of the study period. Mechanical complications involving a slight misfit of the crown margin were recorded for one unit (1%), porcelain fracture for 16 units (16%), and a loss of preload for 12 units (12%) of < 5 Ncm (< 20% of initial preload). Conclusion: The biologic and mechanical stability of ceramic crowns bonded to CAD/ CAM screw-retained abutments using angulated screw access was considered to be high, with overall bone gain, excellent soft tissue health, and only limited mechanical complications related to generally small fractures of the porcelain and a clinically insignificant loss of preload. Int J Oral Maxillofac Implants 2023;38:37–45. doi: 10.11607/jomi.9856

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Biologic and Mechanical Stability of Screw-Retained Layered Zirconia Crowns Bonded to CAD/CAM Titanium Abutments Using Angulated Screw Access: A Prospective Closed Cohort Study
Date Crossref
01/01/2023
Éditeur
Quintessence Publishing
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les sujets associés

Dental Implant Techniques and OutcomesBone Tissue Engineering MaterialsDental materials and restorations

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.