Excluding prepontine cistern from whole ventricle radiotherapy target volume in localized germinoma
Rattachement africain : kr. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
PURPOSE: The target delineation of whole ventricle radiotherapy (WVRT) in germinoma varies among radiation oncologists, especially regarding the inclusion of the prepontine cistern (PC). We evaluated the outcome of PC-sparing WVRT in localized germinoma. MATERIALS AND METHODS: We identified 87 localized intracranial germinoma patients who received radiotherapy (RT) following chemotherapy between 1999 and 2020. By institutional policy, RT for localized germinoma excluded PC from the target volume. WVRT was delivered to 65 patients (74.7%) and involved field radiotherapy (IFRT) to 22 patients (25.3%). The median dose was 45.0 Gy (range, 23.4 to 55.8 Gy) for the primary tumor and 19.8 Gy (rangem 14.4 to 36.0 Gy) for the whole ventricle. We analyzed the dosimetric differences of the organs at risk between the PC-excluding plans and the PC-including ones. RESULTS: The median follow-up duration was 7.8 years (range, 1.0 to 22.5 years). The 10-year recurrence-free survival and overall survival rates were 86.3% and 90.9%, respectively. The recurrences occurred in eight patients (8.7%), including five patients after IFRT and three after WVRT. Five of them showed recurrences at lateral ventricles and only one patient experienced spinal cord relapse. However, no relapse in the PC occurred. Endoscopic third ventriculostomy was not a significant prognostic factor. The dosimetric comparisons showed significantly lower mean doses to the brainstem and the cochleae when the PC was excluded. CONCLUSION: WVRT for localized germinoma can safely exclude the PC in the target volume, reducing radiation dose to the brain stem. The target protocol needs to reach a consensus regarding the PC in prospective trials.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Excluding prepontine cistern from whole ventricle radiotherapy target volume in localized germinoma
- Date Crossref
- 31/03/2023
- Éditeur
- Korean Society for Therapeutic Radiology and Oncology
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.