Identification and diagnosis of mammographic malignant architectural distortion using a deep learning based mask regional convolutional neural network
Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: Architectural distortion (AD) is a common imaging manifestation of breast cancer, but is also seen in benign lesions. This study aimed to construct deep learning models using mask regional convolutional neural network (Mask-RCNN) for AD identification in full-field digital mammography (FFDM) and evaluate the performance of models for malignant AD diagnosis. Methods: This retrospective diagnostic study was conducted at the Second Affiliated Hospital of Guangzhou University of Chinese Medicine between January 2011 and December 2020. Patients with AD in the breast in FFDM were included. Machine learning models for AD identification were developed using the Mask RCNN method. Receiver operating characteristics (ROC) curves, their areas under the curve (AUCs), and recall/sensitivity were used to evaluate the models. Models with the highest AUCs were selected for malignant AD diagnosis. Results: A total of 349 AD patients (190 with malignant AD) were enrolled. EfficientNetV2, EfficientNetV1, ResNext, and ResNet were developed for AD identification, with AUCs of 0.89, 0.87, 0.81 and 0.79. The AUC of EfficientNetV2 was significantly higher than EfficientNetV1 (0.89 vs. 0.78, P=0.001) for malignant AD diagnosis, and the recall/sensitivity of the EfficientNetV2 model was 0.93. Conclusion: The Mask-RCNN-based EfficientNetV2 model has a good diagnostic value for malignant AD.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Identification and diagnosis of mammographic malignant architectural distortion using a deep learning based mask regional convolutional neural network
- Date Crossref
- 22/03/2023
- Éditeur
- Frontiers Media SA
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Guangzhou University of Chinese Medicine Department of Radiology pays non établi dans la noticeUniversité ou école supérieure
-
Beijing Academy of Artificial Intelligence pays non établi dans la noticeInstitution
-
Ltd Department of Engineering pays non établi dans la noticeEntreprise
-
Research Lab Artificial Intelligence (AI) pays non établi dans la noticeStructure de recherche
Department of Radiology — Guangzhou University of Chinese Medicine, Beijing Academy of Artificial Intelligence et Department of Engineering — Ltd, avec 1 autre affiliation.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.