Efficiency evaluation of a SARS-CoV-2 diagnostic strategy combining high throughput quantitative antigen immunoassay and real time PCR
Rattachement africain : ch. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVES: Laboratory testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has played an important role in the effort to prevent and contain local outbreaks. The aim of this study was to assess the diagnostic accuracy of a new fully automated SARS-CoV-2 laboratory-based antigen assay (CoV2Ag) and to explore the efficiency of a diagnostic algorithm combining antigen and conventional high-throughput molecular assays to address potential future challenges of the SARS-CoV-2 pandemic. METHODS: One thousand two hundred and twenty four consecutive nasopharyngeal swabs were tested using RT-PCR and CoV2Ag assay. RESULTS: The overall sensitivity and specificity of CoV2Ag were 79.1 and 97.8%, respectively. When the analysis was restricted to cases with Ct values ≤30, the sensitivity of the assay improved to 98.1%. Acceptable sensitivity was found when the analysis was limited to patients presenting within one or two to four days of symptom onset (80.5 and 84.8%, respectively). A retrospective analysis of the use of a two-step diagnostic approach combining the CoV2Ag assay and RT-PCR during an acute pandemic phase of 97 days showed a potential reduction in the number of RT-PCR tests by 36.1%, corresponding to savings in reagent costs and technician workload of approximately €8,000 and 10.5 h per day, respectively. CONCLUSIONS: Our data show that the proposed algorithm represents a valid alternative diagnostic approach to increase testing efficiency during future pandemic phases with high positivity rates (>20%) and elevated numbers of RT-PCR test requests.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Efficiency evaluation of a SARS-CoV-2 diagnostic strategy combining high throughput quantitative antigen immunoassay and real time PCR
- Date Crossref
- 22/03/2023
- Éditeur
- Walter de Gruyter GmbH
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.