Aller au contenu principal
Accès ouvert déclaré 2023 article

Serological testing for Hansen’s disease diagnosis: Clinical significance and performance of IgA, IgM, and IgG antibodies against Mce1A protein

7Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : br, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Hansen’s disease (HD) is an infectious, treatable, and chronic disease. It is the main cause of infectious peripheral neuropathy. Due to the current limitations of laboratory tests for the diagnosis of HD, early identification of infected contacts is an important factor that would allow us to control the magnitude of this disease in terms of world public health. Thus, a cross-sectional study was conducted in the Brazilian southeast with the objective of evaluating humoral immunity and describing the accuracy of the immunoassay based on IgA, IgM, and IgG antibodies against surface protein Mce1A of Mycobacterium, the predictive potential of these molecules, the clinical significance of positivity, and the ability to segregate new HD cases (NC; n = 200), contacts (HHC; n = 105), and healthy endemic controls (HEC; n = 100) as compared to α-PGL-I serology. α-Mce1A levels for all tested antibodies were significantly higher in NC and HHC than in HEC (p < 0.0001). The performance of the assay using IgA and IgM antibodies was rated as highly accurate (AUC > 0.85) for screening HD patients. Among HD patients (NC), positivity was 77.5% for IgA α-Mce1A ELISA, 76.5% for IgM, and 61.5% for IgG, while α-PGL-I serology showed only 28.0% positivity. Multivariate PLS-DA showed two defined clusters for the HEC and NC groups [accuracy = 0.95 (SD = 0.008)] and the HEC and HHC groups [accuracy = 0.93 (SD = 0.011)]. IgA was the antibody most responsible for clustering HHC as compared to NC and HEC, evidencing its usefulness for host mucosal immunity and as an immunological marker in laboratory tests. IgM is the key antibody for the clustering of NC patients. Positive results with high antibody levels indicate priority for screening, new clinical and laboratory evaluations, and monitoring of contacts, mainly with antibody indexes ≥2.0. In light of recent developments, the incorporation of new diagnostic technologies permits to eliminate the main gaps in the laboratory diagnosis of HD, with the implementation of tools of greater sensitivity and accuracy while maintaining satisfactory specificity.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Serological testing for Hansen’s disease diagnosis: Clinical significance and performance of IgA, IgM, and IgG antibodies against Mce1A protein
Date Crossref
16/03/2023
Éditeur
Frontiers Media SA
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Leprosy Research and TreatmentInfectious Diseases and TuberculosisMycobacterium research and diagnosis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.