Staphylococcus aureus bacteraemia, cardiac implantable electronic device, and the risk of endocarditis: a retrospective population–based cohort study
Rattachement africain : se. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Patients with cardiac implantable electronic device (CIED) and Staphylococcus aureus bacteraemia (SAB) are at risk of having infective endocarditis (IE). The objectives were to describe a Swedish population-based cohort of patients with CIED and SAB, to identify risk factors, and to construct a predictive score for IE. Patients over 18 years old in the Stockholm Region identified to have SAB in the Karolinska Laboratory database from January 2015 through December 2019 were matched to the Swedish Pacemaker and Implantable Cardioverter-Defibrillator ICD Registry to identify the study cohort. Data were collected from study of medical records. A cohort of 274 patients with CIED and SAB was identified and in 38 episodes (14%) IE were diagnosed, 19 with changes on the CIED, and 35 with changes on the left side of the heart. The risk factors predisposition for IE, community acquisition, embolization, time to positivity of blood cultures, and growth in blood culture after start of therapy in blood cultures were independently associated to IE. A score to identify patients with IE was constructed, the CTEPP score, and the chosen cut-off generated a sensitivity of 97%, specificity of 25%, and a negative predictive value of 98%. The score was externally validated in a population-based cohort of patients with CIED and SAB from another Swedish region. We found that 14% of patients with CIED and SAB had definite IE diagnosed. The CTEPP-score can be used to predict the risk of IE and, when negative, the risk is negligible.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Staphylococcus aureus bacteraemia, cardiac implantable electronic device, and the risk of endocarditis: a retrospective population–based cohort study
- Date Crossref
- 15/03/2023
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Karolinska University Hospital Department of Infectious Diseases pays non établi dans la noticeÉtablissement de santé
-
Karolinska Institutet Unit of Infectious Diseases pays non établi dans la noticeUniversité ou école supérieure
-
Lund University Department of Clinical Sciences Lund pays non établi dans la noticeUniversité ou école supérieure
-
Skåne University Hospital Division for Infectious Diseases pays non établi dans la noticeÉtablissement de santé
Department of Infectious Diseases — Karolinska University Hospital, Unit of Infectious Diseases — Karolinska Institutet et Department of Clinical Sciences Lund — Lund University, avec 1 autre affiliation.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.