Aller au contenu principal
Accès ouvert déclaré 2023 article

Surgeon-designed patient-specific instrumentation improves glenoid component screw placement for reverse total shoulder arthroplasty in a population with small glenoid dimensions

13Citations signalées — pas une note de qualité
5Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

PURPOSE: Glenoid component loosening is a potential complication of reverse total shoulder arthroplasty (rTSA), occurring in part due to lack of adequate screw purchase in quality scapular bone stock. This study was to determine the efficacy of a surgeon-designed, 3D-printed patient-specific instrumentation (PSI) compared to conventional instrumentation (CI) in achieving longer superior and inferior screw lengths for glenoid component fixation. METHODS: A multi-centre retrospective analysis of patients who underwent rTSA between 2015 and 2020. Lengths of the superior and inferior locking screws inserted for fixation of the glenoid baseplate component were recorded and compared according to whether patients received PSI or CI. Secondary outcomes included operative duration and incidence of complications requiring revision surgery. RESULTS: Seventy-three patients (31 PSI vs. 42 CI) were analysed. Average glenoid diameter was 24.5 mm (SD: 3.1) and 81% of patients had smaller glenoid dimensions compared to the baseplate itself. PSI produced significantly longer superior (44.7 vs. 30.7 mm; P < 0.001) and inferior (43.0 vs. 31 mm; P < 0.001) mean screw lengths, as compared to CI. A greater proportion of maximal screw lengths for the given rTSA construct (48 mm) were observed in the PSI group (71.9% vs. 11.9% superior, 59.4% vs. 11.9% inferior). Operative duration was not statistically significantly different between the PSI and CI groups (150 min vs. 169 min, respectively; P = 0.229). No patients had radiographic loosening of the glenoid component with an average of 2-year follow-up. CONCLUSION: PSI facilitates longer superior and inferior screw placement in the fixation of the glenoid component for rTSA. With sufficient training, PSI can be designed and implemented by surgeons themselves.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Surgeon-designed patient-specific instrumentation improves glenoid component screw placement for reverse total shoulder arthroplasty in a population with small glenoid dimensions
Date Crossref
10/02/2023
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Shoulder Injury and TreatmentShoulder and Clavicle InjuriesNerve Injury and Rehabilitation

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.