Aller au contenu principal
Accès ouvert déclaré 2023 article

Prevalence of reduced lung diffusing capacity and CT scan findings in smokers without airflow limitation: a population-based study

8Citations signalées, ce qui n’est pas une note de qualité
13Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : es. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Population distribution of reduced diffusing capacity of the lungs for carbon monoxide (DLCO) in smokers and main consequences are not properly recognised. The objectives of this study were to describe the prevalence of reduced DLCO in a population-based sample of current and former smoker subjects without airflow limitation and to describe its morphological, functional and clinical implications. METHODS: A sample of 405 subjects aged 40 years or older with postbronchodilator forced expiratory volume in 1 s/forced vital capacity (FVC) >0.70 was obtained from a random population-based sample of 9092 subjects evaluated in the EPISCAN II study. Baseline evaluation included clinical questionnaires, exhaled carbon monoxide (CO) measurement, spirometry, DLCO determination, 6 min walk test, routine blood analysis and low-dose CT scan with evaluation of lung density and airway wall thickness. RESULTS: In never, former and current smokers, prevalence of reduced DLCO was 6.7%, 14.4% and 26.7%, respectively. Current and former smokers with reduced DLCO without airflow limitation were younger than the subjects with normal DLCO, and they had greater levels of dyspnoea and exhaled CO, greater pulmonary artery diameter and lower spirometric parameters, 6 min walk distance, daily physical activity and plasma albumin levels (all p<0.05), with no significant differences in other chronic respiratory symptoms or CT findings. FVC and exhaled CO were identified as independent risk factors for low DLCO. CONCLUSION: Reduced DLCO is a frequent disorder among smokers without airflow limitation, associated with decreased exercise capacity and with CT findings suggesting that it may be a marker of smoking-induced early vascular damage. TRIAL REGISTRATION NUMBER: NCT03028207.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Prevalence of reduced lung diffusing capacity and CT scan findings in smokers without airflow limitation: a population-based study
Date Crossref
01/01/2023
Éditeur
BMJ
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Chronic Obstructive Pulmonary Disease (COPD) ResearchHeme Oxygenase-1 and Carbon MonoxideAir Quality and Health Impacts

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.