Aller au contenu principal
Accès ouvert déclaré 2023 article

Application of the method of ordinary least squares in the calibration of temperature, pressure and mass meters

1Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : co, mx. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The goal of this paper is applied the Ordinary Least Squares (OLS) method as a strategy in order to reduce the uncertainty measurement associated to the relevant physical quantities. Methodology or method: This work was motivated due to the efforts made in the measurement sciences to investigate alternative methods that allow obtaining greater metrological reliability of the results, that is, reducing the uncertainty associated with the measurement. Thus, the applied methodology consisted of the development of a computational code using the MatLab tool, in which an algorithm was programmed that supports the application of the OLS method. Three of the most used physical magnitudes at an industrial level were evaluated: temperature, pressure and mass. These magnitudes were evaluated from the calibration of three measuring instruments: thermistor, manometer and digital scale. Results: The applied methodology allowed to: (i) obtain the matrix of the coefficients for polynomials of degrees 1, 2, 3 and 4 that adjust the experimental data; (ii) to draw the calibration curves for each of the obtained polynomials and (iii) to estimate the fit uncertainty (i.e.: the mean squared deviation) to specify the polynomial that best models the experimental data for a reliability level of 95.45 % (k = 2). The consolidated results confirmed a reduction in the uncertainty associated with the adjustment polynomial of 99.8% for the temperature measurement, 45.6% for the pressure measurement and 53.9% for the mass measurement. Conclusions: Finally, a discussion of the results is presented, confirming the effectiveness of the ordinary least squares method as a strategy to reduce the uncertainty associated with the calibration of measuring instruments.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Application of the method of ordinary least squares in the calibration of temperature, pressure and mass meters
Date Crossref
17/01/2023
Éditeur
Universidad Simon Bolivar
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Sensor Technology and Measurement SystemsScientific Measurement and Uncertainty EvaluationAdvanced Sensor Technologies Research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.