Aller au contenu principal
2022 conference-paper

Detection of SARS-CoV-2 by RT-LAMP assay in Human COVID-19 patients

1Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : pk. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: The novel COVID-19 outbreak has infected human population all around the world. Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) diagnosis in a rapid manner remains challenging for health care professionals. Currently, RT-qPCR technique is extensively practiced in SARS-CoV-2 diagnosis and is considered as gold standard. The constraints of RT-qPCR, high cost and need for trained technician, longer detection time, highlighted the need for alternate healthcare diagnostic approaches. They follow the WHO assured standard and offer the health-care sector optimism. One of them is the Loop Mediated isothermal amplification system (LAMP). There is no need for costly equipment like thermal cycler since LAMP assay is performed at a fixed temperature. It can also be implemented as a point of care testing device. RT-LAMP is one of the extensively used isothermal amplification system in pathogen diagnostics.Aims: The current study aims to validate and standardize RT-LAMP assay for rapid diagnosis of SARS-CoV-2 in both lab and field conditions. The reactions can be carried out using a heating vessel including the use of a water bath and end-point detection by colorimetry. A rising middle ground of tiny, more portable technology, that provides most of the capability at less cost and time.Methods and Results: 20 Samples were taken from COVID-19 positive patients. RNA extraction from COVID-19 samples was followed up by one-step reverse transcription and loop-mediated isothermal amplification (LAMP). LAMP primers were designed to amplify the conserved regions of SARS-COV-2 specific genes. The target regions for primer design were selected after genome-wide sequence alignment of SARS-CoV-2 strains isolated in various regions of the world i.e., Europe, Africa, Asia, and North America. RT-LAMP assays were performed at the specific incubation temperature (60°C) for 50 minutes. Assay was optimized as per consumable compatibility, COVID template integrity, primer concentration, template concentration, primer ratio, testing time etc. Sensitivity and specificity of the assay was elucidated. Finally, different end-point analysis i.e., Agarose Gel Electrophoresis and Colorimetry have been used to interpret the results.Conclusion: RT-LAMP assay has shown to be a quick and accurate diagnostic method that can be put to use for SARS-CoV-2 detection in laboratories and Point-of- Care settings.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Detection of SARS-CoV-2 by RT-LAMP assay in Human COVID-19 patients
Date Crossref
16/08/2022
Éditeur
IEEE
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • University of Faisalabad pays non établi dans la notice
    Université ou école supérieure
  • University of Agriculture Faisalabad Institute of Microbiology pays non établi dans la notice
    Université ou école supérieure
  • Center for Advanced Studies in Agriculture and Food Security pays non établi dans la notice
    Structure de recherche

University of Faisalabad, Institute of Microbiology — University of Agriculture Faisalabad et Center for Advanced Studies in Agriculture and Food Security.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Biosensors and Analytical DetectionSARS-CoV-2 detection and testingSARS-CoV-2 and COVID-19 Research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.