Aller au contenu principal
Accès ouvert déclaré 2022 article

Utility of gated SPECT parameters in detection of coronary artery disease in patients with normal perfusion images

2Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : th. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background False negative myocardial perfusion images on single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is a substantial problem in the interpretation of MPI. To explore possible parameters from gated SPECT that could detected coronary artery disease (CAD) in patients with normal perfusion images, we retrospectively selected patients who underwent a 2-day Tc-99 m MIBI adenosine stress/rest MPI and a subsequent invasive coronary angiography. Gated SPECT parameters, including end systolic volume (ESV), end diastolic volume (EDV), left ventricular ejection fraction (LVEF), and transient ischemic dilation (TID) ratio of patients with and without CAD were compared and assessed for their respective diagnostic performance using receiver operating characteristics (ROC) area under the curve (AUC). Results Among 22 patients with normal perfusion images, 7 patients had CAD. Despite the small number of patients, we found significant differences between the ESV, the EDV, and the LVEF between patients with and without CAD. The analysis of ROC curve showed the stress ESV could excellently detect CAD (AUC = 0.900). The rest ESV, the stress EDV, the rest EDV, the stress LVEF and the rest LVEF could likewise perform well in the detection of CAD (AUC = 0.833, 0.819, 0.790, 0.862, and 0.838, respectively). In contrast, the change in LVEF and the TID ratio (AUC = 0.667 and 0.524, respectively) did not seem as reliable as other parameters. Optimal cutoffs for detection of CAD in patients with normal perfusion images from our study were ≥ 20.0 mL for the stress ESV, ≥ 71.0 mL for the stress EDV, ≤ 66.3 EF units for the stress LVEF, ≥ 18.0 mL for the rest ESV, ≥ 67.0 mL for the rest EDV and ≤ 70.0 EF unit for the rest LVEF. Conclusions Gated SPECT parameters could facilitate detection of CAD in patient with normal perfusion images on Tc-99m MIBI MPI. These parameters should be carefully interpreted to improve diagnostic accuracy and reduce false negative MPI.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Utility of gated SPECT parameters in detection of coronary artery disease in patients with normal perfusion images
Date Crossref
15/12/2022
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Imaging and DiagnosticsAdvanced MRI Techniques and ApplicationsAdvanced X-ray and CT Imaging

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.