Comparative analysis of core and perfusion lesion volumes between commercially available computed tomography perfusion software

23Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : fi. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Introduction: Computed tomography perfusion (CTP) imaging has become an important tool in evaluating acute recanalization treatment candidates. Large clinical trials have successfully used RAPID automated imaging analysis software for quantifying ischemic core and penumbra, yet other commercially available software vendors are also on the market. We evaluated the possible difference in ischemic core and perfusion lesion volumes and the agreement rate of target mismatch between OLEA, MIStar, and Syngo.Via versus RAPID software in acute recanalization treatment candidates. Patients and methods: > 6 s with all other software. A perfusion mismatch ratio of ⩾1.8, a perfusion lesion volume of ⩾15 mL, and ischemic core <70 mL was defined as target mismatch. The mean pairwise differences of the core and perfusion lesion volumes between software were calculated using the Bland-Altman method and the agreement of target mismatch between software using the Pearson correlation. Results: A total of 1606 patients had RAPID perfusion maps, 1222 of which had MIStar, 596 patients had OLEA, and 349 patients had Syngo.Via perfusion maps available. Each software was compared with simultaneously analyzed RAPID software. MIStar showed the smallest core difference compared with RAPID (-2 mL, confidence interval (CI) from -26 to 22), followed by OLEA (2 mL, CI from -33 to 38). Perfusion lesion volume differed least with MIStar (4 mL, CI from -62 to 71) in comparison with RAPID, followed by Syngo.Via (6 mL, CI from -94 to 106). MIStar had the best agreement rate with target mismatch of RAPID followed by OLEA and Syngo.Via. Discussion and conclusion: Comparison of RAPID with three other automated imaging analysis software showed variance in ischemic core and perfusion lesion volumes and in target mismatch.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparative analysis of core and perfusion lesion volumes between commercially available computed tomography perfusion software
Date Crossref
01/03/2023
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Acute Ischemic Stroke ManagementAdvanced MRI Techniques and ApplicationsMRI in cancer diagnosis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.