Aller au contenu principal
Accès ouvert déclaré 2022 article

Modelling and Optimization of Heat Absorbed in the Evaporator of Low Temperature Cycle of Two-Step Cascade Refrigeration Systems

0Citations signalées — pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

A single-stage refrigeration system has a low Coefficient of Performance (COP), thus it becomes paramount to have cascade refrigeration systems when there is need to have an evaporator temperature that is below -25 oC. Heat absorbed (QE) in the evaporator of low temperature cycle of two-step cascade refrigeration systems is one of the two parameters that determine the COP of the lower temperature cycle of the two-step refrigeration systems which is also a function of the COP of the cascade refrigeration systems. This research aimed at modelling and optimizing QE of the lower temperature cycle of two-step cascade refrigeration systems using eco-friendly refrigerants. Thermodynamic of the cascade refrigeration systems was performed by varying seven operating parameters using refrigerants R-134a in the High Temperature Cycle (HTC) and R-23 in the Low Temperature Cycle (LTC). Heat absorbed in the evaporator of the lower temperature cycle (QE[LTC]) of the refrigeration systems was optimized using Half Factorial Design of Design-Expert 12.0.1. The influence of the evaporating temperature (TE,HTC), condensing temperature (TC,HTC), cascade temperature difference (ΔTCAS,DIFF), evaporating temperature (TE,LTC), superheating temperature (TSUP,LTC), sub-cooling temperature (TSUB,LTC), and refrigerant mass flow rate (ṁHTC) was investigated on the values of QE[LTC] of the refrigeration systems. The numerical QE[LTC] value is 14.183 while the measured value is 14.81.The study revealed that all the factors having interaction with TC[HTC] and TE[HTC] have a great influence on the value of QE[LTC].

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Modelling and Optimization of Heat Absorbed in the Evaporator of Low Temperature Cycle of Two-Step Cascade Refrigeration Systems
Date Crossref
01/11/2022
Éditeur
Lujosh Ventures Limited
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Refrigeration and Air Conditioning TechnologiesHeat Transfer and OptimizationAdvanced Thermodynamics and Statistical Mechanics