Aller au contenu principal
Accès ouvert déclaré 2022 article

Diagnostic Performance of On-Site Computed Tomography Derived Fractional Flow Reserve on Non-Culprit Coronary Lesions in Patients with Acute Coronary Syndrome

4Citations signalées, ce qui n’est pas une note de qualité
2Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : hu. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The role of coronary computed tomography angiography (CCTA) derived fractional flow reserve (CT-FFR) in the assessment of non-culprit lesions (NCL) in patients with acute coronary syndrome (ACS) is debated. In this prospective clinical study, a total of 68 ACS patients with 89 moderate (30−70% diameter stenosis) NCLs were enrolled to evaluate the diagnostic accuracy of on-site CT-FFR compared to invasive fractional flow reserve (FFRi) and dobutamine stress echocardiography (DSE) as reference standards. CT-FFR and FFRi values ≤0.80, as well as new or worsening wall motion abnormality in ≥2 contiguous segments on the supplying area of an NCL on DSE, were considered positive for ischemia. Sensitivity, specificity, positive, and negative predictive value of CT-FFR relative to FFRi and DSE were 51%, 89%, 75%, and 74% and 37%, 77%, 42%, and 74%, respectively. CT-FFR value (β = 0.334, p < 0.001) and CT-FFR drop from proximal to distal measuring point [(CT-FFR drop), β = −0.289, p = 0.002)] were independent predictors of FFRi value in multivariate linear regression analysis. Based on comparing their receiver operating characteristics area under the curve (AUC) values, CT-FFR value and CT-FFR drop provided better discriminatory power than CCTA-based minimal lumen diameter stenosis to distinguish between an NCL with positive and negative FFRi [0.77 (95% Confidence Intervals, CI: 0.67−0.86) and 0.77 (CI: 0.67−0.86) vs. 0.63 (CI: 0.52−0.73), p = 0.029 and p = 0.043, respectively]. Neither CT-FFR value nor CT-FFR drop was predictive of regional wall motion score index at peak stress (β = −0.440, p = 0.441 and β = 0.403, p = 0.494) or was able to confirm ischemia on the territory of an NCL revealed by DSE (AUC = 0.54, CI: 0.43−0.64 and AUC = 0.55, CI: 0.44−0.65, respectively). In conclusion, on-site CT-FFR is superior to conventional CCTA-based anatomical analysis in the assessment of moderate NCLs; however, its diagnostic capacity is not sufficient to make it a gatekeeper to invasive functional evaluation. Moreover, based on its comparison with DSE, CT-FFR might not yield any information on the microvascular dysfunction in the territory of an NCL.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Diagnostic Performance of On-Site Computed Tomography Derived Fractional Flow Reserve on Non-Culprit Coronary Lesions in Patients with Acute Coronary Syndrome
Date Crossref
08/11/2022
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Coronary Interventions and DiagnosticsCardiac Imaging and DiagnosticsAcute Myocardial Infarction Research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.