A modified 3D stereophotogrammetry-based distraction test for assessing lower eyelid tension

5Citations signalées, ce qui n’est pas une note de qualité
7Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : de, cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

AIM: To investigate the reliability of a modified three-dimensional distraction test (3D-DT) and three-dimensional pinch test (3D-PT) for assessing lower eyelid tension (LET). METHODS: A cross-sectional study was conducted among 97 volunteers including 97 eyelids with no history of trauma, tumor, or reconstructive surgeries. Six three-dimensional photographs were acquired for each participant, including two photographs obtained in a neutral position (NP), two using a modified 3D-DT with a 15.9-grammes stainless steel eyelid hook performed, and two using 3D-PT. RESULTS: The mean absolute differences between NP, 3D-DT, and 3D-PT measurements varied between 0.07 and 7.42, 0.10 and 13.10, and 0.07 and 15.97, respectively; technical error of measurement varied between 0.05 and 7.81, 0.09 and 10.19, and 0.07 and 12.47, respectively; and relative error measurements varied between 0.10% and 11.50%, 0.16% and 30.51%, and 0.11% and 38.75%, respectively. For intra-rater reliability, the intraclass correlation coefficients (ICCs) were more than 0.80 in seven out of eight measurements obtained in the NP and 3D-DT, whereas those obtained in the 3D-PT were as low as less than 0.30 by rater 1; the ICCs of all the measurements obtained in all the positions (NP, 3D-DT, and 3D-PT) were more than 0.80 by rater 2. For inter-rater reliability six out of eight NP and 3D-DT measurements had an ICC greater than 0.80, whereas those of 3D-PT measurements were less than 0.30. For intra-method reliability, the ICCs of all the NP measurements were more than 0.87, whereas those of the six 3D-DT measurements and four 3D-PT measurements were more than 0.80. CONCLUSION: Our study results prove that the modified 3D-DT, which involves the use of an eyelid hook, can be a highly reliable method for evaluating LET. Furthermore, this novel and simple method may be utilized as the basis for further investigation and routine pre- and postoperative clinical evaluation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A modified 3D stereophotogrammetry-based distraction test for assessing lower eyelid tension
Date Crossref
18/11/2022
Éditeur
Press of International Journal of Ophthalmology (IJO Press)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Craniofacial Disorders and TreatmentsDigital Imaging in MedicinePediatric Pain Management Techniques

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.