Aller au contenu principal
Accès ouvert déclaré 2022 article

Microvascular anastomosis in a challenging setting using a 4 K three-dimensional exoscope compared with a conventional microscope: An in vivo animal study

6Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background Three-dimensional (3D) exoscope systems have been developed and are reported to be adequate alternatives to the conventional microscope. This study aimed to evaluate the feasibility and effectivity of microvascular anastomosis using a 4 K 3D exoscope in an in vivo animal study. Methods The abdominal aortas of mice were selected as the target vessels for comparing the outcomes of microvascular anastomosis for both the conventional microscope and 3D exoscope. We recorded the vessel separation, temporary occlusion, and total procedure durations. Local conditions at the sutures were also recorded. Typical histopathological images were presented, and the patency of anastomotic vessels within 5 and 30 min were evaluated. All procedures included both superficial and deep anastomosis. Results Sixty mice were included in the analysis; the weight and vascular diameter were 38.5 ± 5.8 g and 0.77 ± 0.06 mm, respectively, and around 8 stiches were required. Regarding feasibility, vessel separation duration, temporary occlusion duration, total procedure duration, blood leak, and number of vascular folds between stiches, the results were comparable between the two types of microscopes. The feasibility of anastomosis was also confirmed by pathology. Regarding effectiveness, anastomotic vascular patency at 5 and 30 min were similar for both microscopes. Even in the more difficult scenario of deep anastomosis, the results were comparable. Conclusions In a challenging experimental setting, comparable outcomes of microvascular anastomosis were observed for the conventional microscope and 3D exoscope in these animal experiments. Therefore, in vivo microvascular anastomosis is feasible and effective using a 3D exoscope.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Microvascular anastomosis in a challenging setting using a 4 K three-dimensional exoscope compared with a conventional microscope: An in vivo animal study
Date Crossref
20/10/2022
Éditeur
Frontiers Media SA
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Surgical Simulation and TrainingMinimally Invasive Surgical TechniquesColorectal Cancer Surgical Treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.