Aller au contenu principal
Accès ouvert déclaré 2022 article

Comparative efficacy of finger versus forehead Plethysmographic Variability Index monitoring in pediatric surgical patients

2Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : tr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

INTRODUCTION: The Plethysmographic Variability Index can be measured by both finger and forehead probes. Vasoconstriction may jeopardize the reliability of finger PVI measurements in pediatric patients undergoing surgery. However, forehead vasculature exhibits more marked resistance to alterations in the vasomotor tonus. OBJECTIVE: Our aim was to compare the Plethysmographic Variability Index measured via finger or forehead probes in mechanically ventilated pediatric surgery patients in terms of their ability to predict fluid responsiveness as well as to determine the best cut-off values for these two measurements. MATERIALS AND METHODS: A total of 50 pediatric patients undergoing minor elective surgery were included after provision of parental consent and ethics committee approval. Perfusion index measured at the finger or forehead and Plethysmographic Variability Index monitoring comprised the primary assessments. Hemodynamic parameters monitored included perfusion index, Plethysmographic Variability Index, and cardiac output. A ≥ 15% increase in cardiac output following passive leg raise maneuver was considered to show fluid responsiveness. Two groups were defined based on fluid responsiveness: Group R (responsive) and Group NR (non-responsive). Student's t-test, Mann-Whitney U test, DeLong test, and ROC were used for statistical analysis. RESULTS: The area under curve for finger and forehead Plethysmographic Variability Index prior to passive leg raise maneuver were 0.699 (p = .011) and 0.847 (p < .001), respectively. The sensitivity for finger and forehead measurements at a cut-off value of ≤14% was 92.9% and 96.4%, and 45.4% and 72.7%, respectively. CONCLUSION: Although forehead and finger Plethysmographic Variability Index monitoring were similarly sensitive in predicting fluid responsiveness in pediatric surgical patients, the former method provided higher specificity. The best cut-off value for PVI measurements with forehead and finger probes was found to be 14%.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Comparative efficacy of finger versus forehead Plethysmographic Variability Index monitoring in pediatric surgical patients
Date Crossref
17/10/2022
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Hemodynamic Monitoring and TherapyBody Composition Measurement TechniquesSepsis Diagnosis and Treatment

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.