Aller au contenu principal
Accès ouvert déclaré 2022 article

Cardiorespiratory Fitness and Neuromuscular Function of Mechanically Ventilated ICU COVID-19 Patients*

9Citations signalées, ce qui n’est pas une note de qualité
16Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : fr, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

OBJECTIVES: The aim of the current study was to investigate the level of cardiorespiratory fitness and neuromuscular function of ICU survivors after COVID-19 and to examine whether these outcomes are related to ICU stay/mechanical ventilation duration. DESIGN: Prospective nonrandomized study. SETTING: Patients hospitalized in ICU for COVID-19 infection. PATIENTS: Sixty patients hospitalized in ICU (mean duration: 31.9 ± 18.2 d) were recruited 4-8 weeks post discharge from ICU. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Patients visited the laboratory on two separate occasions. The first visit was dedicated to quality of life questionnaire, cardiopulmonary exercise testing, whereas measurements of the knee extensors neuromuscular function were performed in the second visit. Maximal oxygen uptake (V o2 max) was 18.3 ± 4.5 mL·min -1 ·kg -1 , representing 49% ± 12% of predicted value, and was significantly correlated with ICU stay/mechanical ventilation (MV) duration ( R = -0.337 to -0.446; p < 0.01 to 0.001), as were maximal voluntary contraction and electrically evoked peak twitch. V o2 max (either predicted or in mL· min -1 ·kg -1 ) was also significantly correlated with key indices of pulmonary function such as predicted forced vital capacity or predicted forced expiratory volume in 1 second ( R = 0.430-0.465; p ≤ 0.001) and neuromuscular function. Both cardiorespiratory fitness and neuromuscular function were correlated with self-reported physical functioning and general health status. CONCLUSIONS: V o2 max was on average only slightly above the 18 mL·min -1 ·kg -1 , that is, the cut-off value known to induce difficulty in performing daily tasks. Overall, although low physical capacities at admission in ICU COVID-19 patients cannot be ruled out to explain the association between V o2 max or neuromuscular function and ICU stay/MV duration, altered cardiorespiratory fitness and neuromuscular function observed in the present study may not be specific to COVID-19 disease but seem applicable to all ICU/MV patients of similar duration.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Cardiorespiratory Fitness and Neuromuscular Function of Mechanically Ventilated ICU COVID-19 Patients*
Date Crossref
14/09/2022
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Intensive Care Unit Cognitive DisordersLong-Term Effects of COVID-19Respiratory Support and Mechanisms

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.