Aller au contenu principal
2022 article

Derivo embolization device for intracranial aneurysms: a Spanish multicenter retrospective study

9Citations signalées, ce qui n’est pas une note de qualité
11Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : es, it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Flow diverters have emerged in recent years as a safe and effective treatment for intracranial aneurysms, with expanding indications. The Derivo embolization device (DED) is a second-generation flow diverter with a surface finish that may reduce thrombogenicity. We report our multicenter experience evaluating its safety and efficacy. METHODS: We retrospectively analyzed all patients treated with the DED in eight centers in Spain between 2016 and 2020. Demographics, clinical data, procedural complications, morbidity and aneurysm occlusion rates were collected. RESULTS: A total of 209 patients with 250 aneurysms were treated (77.5% women). The majority of aneurysms were located in the internal carotid artery (86.8%) and most (69.2%) were small (<10 mm) with a median maximum diameter of 5.85 mm and median neck size of 4 mm. DED deployment was successful in all cases, despite two malfunctioning devices (1%). Major complications occurred in nine patients (4.3%), while mild neurologic clinical events were registered in 23 (11%); four patients died (1.9%). A total of 194 aneurysms had an angiographic follow-up at 6 months and showed complete aneurysm occlusion in 75% of cases. Twelve-month follow-up was available for 112 of the treated aneurysms, with a total occlusion rate of 83%. CONCLUSION: The DED is a second-generation surface-modified flow diverter that presents an option for treatment of intracranial aneurysms with comparable safety and efficacy to other available flow diverter devices. Nonetheless, risks are not negligible, and must be balanced against the natural history risk of cerebral aneurysms, considering the tendency to widen indications for treatment of smaller and less complex lesions in day-to-day use.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Derivo embolization device for intracranial aneurysms: a Spanish multicenter retrospective study
Date Crossref
23/08/2022
Éditeur
BMJ
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Intracranial Aneurysms: Treatment and ComplicationsVascular Malformations Diagnosis and TreatmentIntracerebral and Subarachnoid Hemorrhage Research

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.