Aller au contenu principal
Accès ouvert déclaré 2022 article

Bacilloscopy and polymerase chain reaction of slit-skin smears and anti-phenolic glycolipid-I serology for Hansen’s disease diagnosis

16Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : br. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The bacilloscopy of the slit-skin smear (SSS) is the exclusive laboratory test associated with dermato-neurological evaluation for Hansen’s disease (HD) diagnosis; however, it is negative in the majority of PB or primary neural forms. Thus, a PCR technique involving different sequences and target genes has been performed with an aim to increase the sensitivity and specificity of M. leprae identification, especially in patients with low bacillary loads. Additionally, serological assays based on antibody response reflect infection levels and indicate that this could be a simpler, less invasive technique for estimating M. leprae exposure. Serological tests and PCR have been shown to be more sensitive and accurate than the SSS. Our study aimed to measure accuracy and performance among the SSS and PCR of dermal scrapings stored on filter paper and APGL-I serology for diagnosis in HD. A cross-sectional study analyzing the medical records (n = 345) of an HD outpatient-dermatology clinic from 2014 to 2021 was conducted. Accuracy performance parameters, correlation, and concordance were used to assess the value among the SSS, PCR, and APGL-I exams in HD. The SSS presented 24.5% sensitivity, 100% specificity, 37.4% accuracy, and the lowest negative predictive value (21.5%). The PCR assay had 41, 100, and 51% sensitivity, specificity, and accuracy, respectively. PCR and APGL-I serology increased the detection of HD cases by 16 and 20.6%, respectively. PCR was positive in 51.3% of patients when the SSS was negative. The SSS obtained moderate concordance with PCR [k-value: 0.43 (CI: 0.33–0.55)] and APGL-I [k-value: 0.41 (CI: 0.31–0.53)]. A moderate positive correlation was found between the APGL-I index and the bacillary index (r = 0.53; P < 0.0001). Thus, the use of the SSS is a low sensitivity and accuracy method due to its low performance in HD detection. The use of PCR and serological tests allows for a more sensitive and accurate diagnosis of patients.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Bacilloscopy and polymerase chain reaction of slit-skin smears and anti-phenolic glycolipid-I serology for Hansen’s disease diagnosis
Date Crossref
10/08/2022
Éditeur
Frontiers Media SA
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Leprosy Research and TreatmentBacterial Identification and Susceptibility TestingMycobacterium research and diagnosis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.