Aller au contenu principal
Accès ouvert déclaré 2022 article

PROSE: Prospective Randomized Trial of the On-X Mechanical Prosthesis and the St Jude Medical Mechanical Prosthesis Evaluation

3Citations signalées, ce qui n’est pas une note de qualité
21Institutions déclarées
9Pays d’affiliation déclarés

Rattachement africain : ca, Afrique du Sud, au, in, se, nl, no, de, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Objectives The Prospective Randomized On-X Mechanical Prosthesis Versus St Jude Medical Mechanical Prosthesis Evaluation (PROSE) trial purpose was to investigate whether a current-generation mechanical prosthesis (On-X; On-X Life Technologies/Artivion Inc) reduced the incidence of thromboembolic-related complications compared with a previous-generation mechanical prosthesis (St Jude Medical Mechanical Prosthesis; Abbott/St Jude Medical). This second report documents the valve-related complications by individual prostheses and by Western and Developing populations. Methods The PROSE trial study was conducted in 28 worldwide centers and incorporated 855 subjects randomized between 2003 and 2016. The study enrollment was discontinued on August 31, 2016. The study protocol, and analyses of 10 demographic variables and 24 risk factors were published in detail in 2021. Results The total patient population (N = 855) included patients receiving an On-X valve (n = 462) and a St Jude Medical valve (n = 393). The overall freedom evaluation showed no differences at 5 years between the prostheses for thromboembolism or for valve thrombosis. There were also no differences in mortality. There were several differences between Developing and Western populations. The freedom relations at 5 years for mortality favored Western over Developing populations. Valve thrombosis was differentiated by position and site: aortic < mitral ( P = .007) and Western < Developing ( P = .005). In the mitral position there were no cases in Western populations, whereas there were 8 in Developing populations ( P = .217). Conclusions The On-X valve and St Jude Medical valve performed equally well in the study with no differences found. The only differentiation occurred with valve thrombosis in the mitral position more than the aortic position and occurring in Developing more than Western populations. The occurrence of valve thrombosis was also related to a younger population possibly due to anticoagulation compliance based on record review.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
PROSE: Prospective Randomized Trial of the On-X Mechanical Prosthesis and the St Jude Medical Mechanical Prosthesis Evaluation
Date Crossref
01/12/2022
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsMechanical Circulatory Support DevicesCardiac pacing and defibrillation studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.