Extent and Distribution of Parenchymal Abnormalities in Baseline CT-Scans Do Not Predict Awake Prone Positioning Response in COVID-19 Related ARDS
Rattachement africain : it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Prone positioning is frequently used for non-intubated hypoxemic patients with COVID-19, although conclusive evidence is still lacking. The aim of the present study was to investigate whether baseline CT-scans could predict the improvement in oxygenation in COVID-19 related Acute respira-tory syndrome (ARDS) patients when pronated. Methods: A retrospective study of COVID-19 patients who underwent non-invasive ventilation (NIV) and prone positioning was conducted. Results: Forty-five patients were included. On average, 50% of the overall lung volume was affected by the disease, as observed in the CT-scans, with ground glass opacities (GGOs) and consolidations accounting for 44% and 4%, respectively. The abnormalities were mainly posterior, as demonstrated by posterior/anterior distribution ratios of 1.5 and 4.4 for GGO and consolidation, respectively. The median PaO2/FiO2 ratio during NIV in a supine position (SP1) was 140 [IQR 108–169], which improved by 67% (+98) during prone positioning, on average. Once supine positioning was resumed (SP2), the improvement in oxygenation was maintained in 28 patients (62% of the overall population, categorized as “responders”). We found no significant differences between responders and non-responders in terms of the extent (p = 0.92) and the distribution of parenchymal abnormalities seen in the baseline CT (p = 0.526). Conclusion: Despite the lack of a priori estimation of the sample size, considering the absence of any trends in the differences and correlations, we can reasonably conclude that the baseline chest CT-scan does not predict a gas-exchange response in awake prone-positioned patients with COVID-19 related ARDS. Physicians dealing with this category of patients should not rely on the imaging at presentation when evaluating whether to pronate patients.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Extent and Distribution of Parenchymal Abnormalities in Baseline CT-Scans Do Not Predict Awake Prone Positioning Response in COVID-19 Related ARDS
- Date Crossref
- 30/07/2022
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.