Inter-rater reliability assessment for the new-born screening quality assurance
Résumé fourni par la source
Introduction: To ensure the quality of the new-born screening (NBS), our laboratory reviewed the analytical procedure to detect subjective steps that may represent a risk to the patient. Two subjective activities were identified in the extra-analytical phases: the classification of dried blood spots (DBS) according to their quality and the assignment of haemoglobin patterns. To keep these activities under control, inter-rater studies were implemented. This study aimed to evaluate the inter-rater reliability and the effectiveness of the measures taken to improve the agreement between observers, to assure NBS results' quality. Materials and methods: Dried blood spots specimens were used for the inter-rater studies. Ten studies were performed to assess DBS quality classification, and four to assess the assignment of haemoglobin patterns. Krippendorff's alpha test was used to estimate inter-rater reliability. Causes were investigated when alpha values were below 0.80. Results: For both activities, the reliability obtained in the first studies was inadequate. After investigation, we detected that the criterion to classify a DBS as scant was not consolidated, and also a lack of consensus on whether or not to report Bart's haemoglobin depending on its percentage. Alpha estimates became higher once the training was reinforced and a consensus about the appropriate criteria to be applied was reached. Conclusion: Inter-rater reliability assessment helped us to ensure the quality of subjective activities that could add variability to NBS results. Furthermore, the evolution of the alpha value over time allowed us to verify the effectiveness of the measures adopted.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Inter-rater reliability assessment for the new-born screening quality assurance
- Date Crossref
- 29/09/2022
- Éditeur
- Croatian Society for Medical Biochemistry and Laboratory Medicine
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.
Institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.