Aller au contenu principal
Accès ouvert déclaré 2022 article

Handling and standardization of EBUS needle aspiration in NSCLC patients: The value of the cell block, a monoinstitutional experience

10Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Lung cancer is the main cause of cancer-related death worldwide, and 85% of all lung tumors are non-small cell lung cancers (NSCLC). More than 60% of all lung tumors are diagnosed at an advanced stage, leading to poor prognosis. Given the growing demand for NSCLC profiling for selection of the most appropriate therapy, the acquisition of adequate tumor samples has become increasingly crucial, mostly in advanced NSCLC patients due to old age and/or comorbidities. Being a mini-invasive sampling technique, endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) represents a valuable alternative to traditional transthoracic or surgical sampling in these patients, and perfoming cell block (CB) could be crucial to maximize the potential biological information. The aim of this study is to describe a monoinstitutional interprofessional experience in handling EBUS-TBNA and CB in 464 patients. METHODS: We retrospectively collected all the consecutive CBs obtained from EBUS TBNA performed between 2014 and 2021 on the lung lesions or mediastinal lymph nodes. All the CBs were handled in a standardized method. RESULTS: A total of 95.5% (448/464 samples) of adequacy for site and 92.6% (430/464) of adequacy for diagnosis were observed. Moreover, in the adenocarcinoma histotype, ALK, ROS1 and tumor proportion score (TPS) PD-L1 assessment by IHC was possible in 96% (140/146) of cases, and molecular profile was obtained in 93.8% (137/146) of cases. In the squamous cell carcinoma histotype, TPS PD-L1 assessment was possible in 81% (13/16) of cases. All four CB results obtained from carcinoma NOS were adequate for ALK, ROS1 and PD-L1 assessment and molecular profiling. All 39 metastatic samples from extra-pulmonary primary were adequate for immunohistochemical characterization and molecular profiling. Finally, reporting of the tumor sample adequacy to the clinicians took a median time of about 30 h (range: 24-80 h). CONCLUSION: Careful cytological smear management together with the handling and standardization of CB obtained from EBUS-TBNA could represent an effective method to increase the adequacy of the tumor specimen for both diagnosis and molecular profile.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.

Titre Crossref
Handling and standardization of <scp>EBUS</scp> needle aspiration in <scp>NSCLC</scp> patients: The value of the cell block, a monoinstitutional experience
Date Crossref
22/07/2022
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Lung Cancer Diagnosis and TreatmentCancer Immunotherapy and BiomarkersEsophageal Cancer Research and Treatment

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.