Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis

61Citations signalées — pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Résumé fourni par la source

BACKGROUND: Inertial measurement units (IMUs) are useful in monitoring running and alerting running-related injuries in various sports settings. However, the quantitative summaries of the validity and reliability of the measurements from IMUs during running are still lacking. The purpose of this review was to investigate the concurrent validity and test-retest reliability of IMUs for measuring gait spatiotemporal outcomes and lower extremity kinematics of health adults during running. METHODS: PubMed, CINAHL, Embase, Scopus and Web of Science electronic databases were searched from inception until September 2021. The inclusion criteria were as follows: (1) evaluated the validity or reliability of measurements from IMUs, (2) measured specific kinematic outcomes, (3) compared measurements using IMUs with those obtained using reference systems, (4) collected data during running, (5) assessed human beings and (6) were published in English. Eligible articles were reviewed using a modified quality assessment. A meta-analysis was performed to assess the pooled correlation coefficients of validity and reliability. RESULTS: Twenty-five articles were included in the systematic review, and data from 12 were pooled for meta-analysis. The methodological quality of studies ranged from low to moderate. Concurrent validity is excellent for stride length (intraclass correlation coefficient (ICC) (95% confidence interval (CI)) = 0.937 (0.859, 0.972), p < 0.001), step frequency (ICC (95% CI) = 0.926 (0.896, 0.948), r (95% CI) = 0.989 (0.957, 0.997), p < 0.001) and ankle angle in the sagittal plane (r (95% CI) = 0.939 (0.544, 0.993), p = 0.002), moderate to excellent for stance time (ICC (95% CI) = 0.664 (0.354, 0.845), r (95% CI) = 0.811 (0.701, 0.881), p < 0.001) and good for running speed (ICC (95% CI) = 0.848 (0.523, 0.958), p = 0.0003). The summary Fisher's Z value of flight time was not statistically significant (p = 0.13). Similarly, the stance time showed excellent test-retest reliability (ICC (95% CI) = 0.954 (0.903, 0.978), p < 0.001) and step frequency showed good test-retest reliability (ICC (95% CI) = 0.896 (0.837, 0.933), p < 0.001). CONCLUSIONS: Findings in the current review support IMUs measurement of running gait spatiotemporal parameters, but IMUs measurement of running kinematics on lower extremity joints needs to be reported with caution in healthy adults. TRIAL REGISTRATION: PROSPERO Registration Number: CRD42021279395.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis
Date Crossref
27/06/2022
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Lower Extremity Biomechanics and PathologiesBalance, Gait, and Falls PreventionKnee injuries and reconstruction techniques

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.