Aller au contenu principal
Accès ouvert déclaré 2022 article

Quantitative assessment of radionuclide production yields in in-beam and offline PET measurements at different proton irradiation facilities

2Citations signalées, ce qui n’est pas une note de qualité
11Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : de, ch, fr. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Objective . Reliable radionuclide production yield data are a prerequisite for positron-emission-tomography (PET) based in vivo proton treatment verification. In this context, activation data acquired at two different treatment facilities with different imaging systems were analyzed to provide experimentally determined radionuclide yields in thick targets and were compared with each other to investigate the impact of the respective imaging technique. Approach. Homogeneous thick targets (PMMA, gelatine, and graphite) were irradiated with mono-energetic proton pencil-beams at two distinct energies. Material activation was measured (i) in-beam during and after beam delivery with a double-head prototype PET camera and (ii) offline shortly after beam delivery with a commercial full-ring PET/CT scanner. Integral as well as depth-resolved β + -emitter yields were determined for the dominant positron-emitting radionuclides 11 C, 15 O, 13 N and ( in-beam only) 10 C. In-beam data were used to investigate the qualitative impact of different monitoring time schemes on activity depth profiles and their quantitative impact on count rates and total activity. Main results. Production yields measured with the in-beam camera were comparable to or higher compared to respective offline results. Depth profiles of radionuclide-specific yields obtained from the double-head camera showed qualitative differences to data acquired with the full-ring camera with a more convex profile shape. Considerable impact of the imaging timing scheme on the activity profile was observed for gelatine only with a range variation of up to 3.5 mm. Evaluation of the coincidence rate and the total number of observed events in the considered workflows confirmed a strongly decreasing rate in targets with a large oxygen fraction. Significance . The observed quantitative and qualitative differences between the datasets underline the importance of a thorough system commissioning. Due to the lack of reliable cross-section data, in-house phantom measurements are still considered a gold standard for careful characterization of the system response and to ensure a reliable beam range verification.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Quantitative assessment of radionuclide production yields in in-beam and offline PET measurements at different proton irradiation facilities
Date Crossref
14/07/2022
Éditeur
IOP Publishing
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Radiation Therapy and DosimetryRadiation Detection and Scintillator TechnologiesNuclear Physics and Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.