Safety and Clinical Effectiveness of Pipeline Shield Device for Intracranial Aneurysms in an Australian Cohort (SCOPE‐AUS)

19Citations signalées — pas une note de qualité
7Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Background: The Pipeline Flex Embolization Device (PED) with Shield Technology (PED-Shield) is a third-generation flow diverting stents with surface modification designed to reduce platelet adhesion and thrombogenicity. We report the long-term safety and effectiveness of the PED-Shield in the treatment of unruptured intracranial aneurysms in an Australian cohort. Methods: SCOPE-AUS (Safety and Clinical Effectiveness Of Pipeline Shield Embolization Device for Treatment of Intracranial Aneurysms in Australia) is a multicenter, single-arm, retrospective study of patients with unruptured intracranial aneurysms treated with the PED-Shield flow diverting stents at 3 high-volume neurointervention centers in Australia between May 1, 2015, and June 30, 2018, evaluating safety and efficacy. The primary outcome was neurologic adverse event or neurologic-related death at 1 year, and the secondary outcome was long-term complete aneurysm occlusion. Results: A total of 238 patients (mean age 55.8±11.0 years, 73.1% [174/238] female) and 278 aneurysms were treated via 247 procedures. Two (0.7%) aneurysms were retreated during the 18-month follow-up. Overall occlusion rates at 18 months or at last follow-up imaging were 92.5% (233/252). There were 35 (14.7%) total primary end point events. The 12-month neurologic morbidity and mortality rates were 3.8% (9/238) and 1.3% (3/238), respectively. For the subgroup of internal carotid artery aneurysms, mortality (0.7%) and morbidity (2.0%) rates were low, and the complete occlusion rate was 92.5% (147/155). Conclusions: In this multicenter study, which includes a wide variety of both distal bifurcation and proximal unruptured intracranial aneurysms, the occlusion rates and safety outcomes of the PED-Shield flow diverting stent demonstrate a high proportion of complete aneurysm occlusion, extremely low retreatment rates, and low complication rates.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Safety and Clinical Effectiveness of Pipeline Shield Device for Intracranial Aneurysms in an Australian Cohort (SCOPE‐AUS)
Date Crossref
01/09/2022
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Intracranial Aneurysms: Treatment and ComplicationsCerebrovascular and Carotid Artery DiseasesVascular Anomalies and Treatments

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.