Aller au contenu principal
Accès ouvert déclaré 2022 article

Influence of Implant Diameter and Taper on Virtual Implant Placement in the Maxillary Central Incisor Position: A CBCT Analysis

3Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

PURPOSE: This study aimed to assess the influence of implant diameter and taper on the proximity of virtually planned maxillary central incisor implants to the nasopalatine canal and adjacent anatomical structures. MATERIALS AND METHODS: Virtual implant planning was performed in the maxillary central incisor position. The distance between the implant and the incisive canal (IC) and the thickness of the surrounding buccal and palatal bone walls were measured. Implants were categorized as having an exposed implant surface, thin bone, or moderate/thick bone. Measurements were repeated for regular-/narrow-diameter and parallel/tapered implants. RESULTS: A total of 60 patients were included, and 240 implants (60 of each type: 3.3-bone level [BL], 3.3-bone level tapered [BLT], 4.1-BL, and 4.1-BLT) were planned. The percentages of implants with between 0 and 0.5 mm of remaining bone in the coronal aspect of the IC were 31.6% for 4.1-BL/BLT and 6.6% for 3.3-BL/BLT (P < .001). The percentage of implants with IC exposure was 13.3% for 4.1-BL/BLT and 6.6% for 3.3-BL/BLT (P < .001). The frequency of sites that required bone augmentation at the coronal facial aspect (< 1 mm) was 52.6% and 33.9% for 4.1-BL/BLT and 3.3-BL/BLT, respectively. At the apical portion, the percentages of sites requiring bone augmentation at the facial aspect were 59.9%, 49.9%, 31.6%, and 23.3% for 4.1-BL, 3.3-BL, 4.1-BLT, and 3.3-BLT, respectively (P < .001). CONCLUSION: The proximity of the nasopalatine canal is often < 0.5 mm from regular-diameter virtually planned implants at the most coronal aspect in the maxillary central incisor position. In these situations, the selection of narrowdiameter implants significantly lowers the incidence of implant exposure and the need for additional management of the nasopalatine canal and also results in greater residual buccal and lingual bone thicknesses surrounding the implant. As expected, tapered implants reduced the risk of implant exposure through the buccal cortex at the apical aspect.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Influence of Implant Diameter and Taper on Virtual Implant Placement in the Maxillary Central Incisor Position: A CBCT Analysis
Date Crossref
01/05/2022
Éditeur
Quintessence Publishing
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les sujets associés

Dental Implant Techniques and OutcomesDental Radiography and ImagingEndodontics and Root Canal Treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.