We report a novel strategy for decentralized monitoring of gaseous elemental mercury (GEM), Hg(0), in ambient air by a pocket-size low-cost analytical device. The essential components of the system are a gold nanoparticles-modified screen-printed carbon electrode (AuNPs-SPCE) for passive or active sampling by the amalgamation of mercury from the air and a miniaturized potentiostat (pen drive size). The potentiostat was connected to a smartphone for the determination of the amount of amalgamated Hg(0) during sampling, by voltammetry on a single 50 µL drop placed onto the AuNPs-SPCE. The method greatly benefits from the nano structuration of the gold electrode, providing a significant analytical improvement in terms of sensitivity and instrumental simplification, compared with a previously reported method based on a gold-sputtered screen-printed electrode. We report the exploration of the electrode surface by SEM, showing efficient adsorption on the nanoparticles due to the higher surface/volume ratio. Inter-electrode reproducibility using a set of three AuNPs-SPCE exposed to a GEM concentration of 5.78 ng dm−3 for sampling times from 0 to 360 min gave an average RSD of 16%. Passive and active sampling gave a similar performance for sampling times higher than 60 min. After 10 min passive sampling, the calibration gave adequate determination coefficients (R2 = 0.990) for the range 5.88–56.39 ng dm−3, with a detection limit of 2.41 ng dm−3. A high sensitivity calibration using 180 min passive sampling for the range 0.23 – 5.69 ng dm−3 of GEM gave R2 = 0.986, with a detection limit of 0.24 ng dm−3.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A pocket-size device for monitoring gaseous elemental mercury by passive sampling on a Nano-Au screen-printed electrode and detection by single drop smartphone-controlled voltammetry
Date Crossref
01/09/2022
Éditeur
Elsevier BV
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Mercury impact and mitigation studiesElectrochemical Analysis and ApplicationsAnalytical chemistry methods development

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref et Europe PMC, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune réponse conservée. Sources et limites.