155 Invasive validation of pressure-volume loops derived from cardiovascular magnetic resonance imaging and brachial blood pressure in heart failure patients

2Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
3Pays d’affiliation déclarés

Rattachement africain : gb, us, se. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Introduction Left ventricular (LV) pressure-volume (PV) loops provide gold-standard physiological information but require invasive measurements of ventricular intracavity pressure, limiting clinical and research applications. Recent development has seen the introduction of non-invasively computed PV loops from cardiovascular magnetic resonance (CMR) volumetry and a brachial blood pressure measurement. The approach combines LV volumes with a time-varying elastance function to compute time-resolved LV pressures and was validated on invasive pressure data from a porcine model. The method is readily implemented using standard CMR sequences and provides measures of hemodynamic parameters including stroke work, myocardial efficiency, and contractile state. However, the method remains to be validated in patients using invasive left ventricular pressure recordings. Purpose To validate for the first time in human patients the performance of non-invasively computed PV loops against invasive measures. Methods. Four heart failure patients underwent two subsequent sessions of CMR cine imaging and simultaneous brachial blood pressure measurement, with intravenous administration of two different vasoactive drugs, resulting in two different haemodynamic states for each patient. LV catheterization was then conducted with repeat administration of the same infusions. Pressure-volume loops were computed from CMR volumes combined with 1) a time-varying elastance function scaled to brachial blood pressure and temporally stretched to match volume data, and 2) invasive pressures averaged from multiple sampled beats. Method comparison was conducted using linear regression and Bland-Altman analysis.Results. Figure 1 (left panel) shows PV loops from one representative patient. The non-invasive method demonstrated strong correlations and low bias compared to invasive data (Fig. 1, right panel) for stroke work, potential energy, end-systolic pressure-volume relationship, energy per ejected volume, ventricular efficiency, arterial elastance, and mean external power (Table 1). Conclusions Pressure-volume loops can be precisely and accurately computed from cardiovascular magnetic resonance imaging and brachial cuff blood pressure in humans, and is ready for use in research applications. Conflict of Interest None

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
155 Invasive validation of pressure-volume loops derived from cardiovascular magnetic resonance imaging and brachial blood pressure in heart failure patients
Date Crossref
01/06/2022
Éditeur
BMJ Publishing Group Ltd and British Cardiovascular Society
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiovascular Function and Risk FactorsCardiac Imaging and DiagnosticsHemodynamic Monitoring and Therapy

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.