Aller au contenu principal
2022 article

Altis® Adjustable Single Incision Sling System for Treatment of Intrinsic Sphincteric Deficiency: A 3-Year Follow-up Observational Study

4Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : mx, it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

IMPORTANCE: This article is a long-term follow-up study on the Altis adjustable single incision sling (Coloplast Corp.) in patients with isolated intrinsic sphincteric deficiency (ISD). OBJECTIVES: The primary end-points were to evaluate the subjective and objective outcomes of the Altis for the treatment of ISD, with a 3-year follow-up. The secondary end-point was to evaluate the safety of this surgical procedure. STUDY DESIGN: This is a retrospective single-arm study. A total of 123 consecutive patients with ISD were selected from our database among women who underwent an Altis implantation for ISD from March 2015 to June 2017, after unsuccessful previous conservative treatment. Of the 123 included patients, 16 were excluded, not meeting inclusion criteria. Cure rate was evaluated objectively, using a standardized cough stress test and urodynamics, and subjectively using the Patient Global Impression of Improvement. Complications were assessed intraoperatively, perioperatively, and postoperatively. Six, 12, and 36 months of follow-ups were analyzed for the study. RESULTS: The 3-year objective cure rate was 86.9%, and the subjective cure rate was 81.5%. We observed no intraoperative complications. No women were obstructed. Ten patients reported postoperative complications, although most of them were Clavien-Dindo grade I and self-limited. CONCLUSIONS: Altis system could be considered an effective and safe alternative to traditional midurethral slings as treatment for women with ISD.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Altis® Adjustable Single Incision Sling System for Treatment of Intrinsic Sphincteric Deficiency: A 3-Year Follow-up Observational Study
Date Crossref
12/05/2022
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Pelvic floor disorders treatmentsGynecological conditions and treatmentsSexual function and dysfunction studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.