763-P: Real-World Use of the MiniMed 780G Advanced Hybrid Closed-Loop (AHCL) System with the Guardian 4 Sensor and the Guardian Sensor 3

2Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Objective: The MiniMed™ 780G system with the adjunctive Guardian™ sensor 3 that requires calibration has been commercially available in Europe, since October 2020. Since October 2021, the system has been available with the non-adjunctive Guardian™ 4 sensor, which does not require calibration. In this study, glycemic outcomes during real-world MiniMed™ 780G system use with both sensors were evaluated. Methods: Analyses were based on data collected on Dec 10, 2021, from consenting system users (N=674) residing in Europe with ≥days of sensor glucose (SG) data from both sensors. Glycemic outcomes including mean±SD of the glucose management indicator (GMI) and percentage of time spent in target range of 70-180mg/dL (TIR) , at <54mg/dL and <70mg/dL (TBR) and at >180mg/dL (TAR) were assessed. The time spent in AHCL, number of AHCL exits/week and self-monitoring of blood glucose (SMBG) measurements/day were also determined. Results: System use with the Guardian™ 4 sensor versus Guardian™ sensor 3 demonstrated 94±9% vs 93±11% of time in AHCL, 73.1±11.4% vs 74.6±9.8% TIR, 0.11±0.16% vs 0.51±0.58% TBR<54, 1.6±1.4% vs 2.4±1.8% TBR<70, and 25.3±11.7% vs 23.1±10.0% TAR<180. During the night (12AM-6AM) , greater glycemic control was observed: with 81.6±13.3% vs 82.8±11.0% TIR, 0.09±0.22% vs 0.42±0.69% TBR<54, 1.1±1.5% vs 1.8±1.9% TBR<70 and 17.3±13.3% vs 15.4±11.0% TAR>180. The GMI was 6.98±0.43% vs 6.84±0.38%. Closed-loop exits were 0.83±1.02 vs 1.1±1.06/week and SMBG measurements were 0.9±0.9 vs 3.3±0.9/day. Conclusion: Real-world MiniMed™ 780G system use findings indicate reduced burden related to SMBG measurements and closed-loop exits, with the Guardian™ 4 sensor, while maintaining favorable glycemic outcomes of the MiniMed™ 780G + Guardian™ sensor 3 system. Disclosure R.A. Vigersky: Employee; Medtronic. J. Castañeda: Employee; Medtronic. A. Arrieta: Employee; Medtronic. T.L. Cordero: Employee; Medtronic, Medtronic. A.S. Rhinehart: Employee; Medtronic. Stock/Shareholder; Medtronic. J. Shin: Employee; Medtronic.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
763-P: Real-World Use of the MiniMed 780G Advanced Hybrid Closed-Loop (AHCL) System with the Guardian 4 Sensor and the Guardian Sensor 3
Date Crossref
01/06/2022
Éditeur
American Diabetes Association
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les sujets associés

Cardiovascular Health and Risk Factors

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.