760-P: Performance of the MiniMed 780G System with the Guardian 4 Sensor—Impact on the First 1,570 Real-World Users

2Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Objective: Since 2021, the MiniMed™ 780G advanced hybrid closed-loop system with the non-adjunctive Guardian™ 4 sensor, that does not require calibration, has been commercially available in Europe. In this study, the real-world glycemic outcomes of the first 1,570 individuals using the system were evaluated. Methods: Analyses were based on data collected since November 2021 from consenting users (N=1,570) in 15 countries who had ≥days of sensor glucose (SG) data. Glycemic outcomes including the mean±SD of the glucose management indicator [GMI], SG, and 24-hour and nighttime percentage of time spent within 70-180mg/dL (TIR) , at <54mg/dL [TBR54], <70mg/dL [TBR70] and >180mg/dL [TAR180] were determined. The mean±SD of time spent in closed loop and the number of closed-loop exits/week were also assessed. Results: For 94±11% of time spent in closed loop, users had an SG of 153±18mg/dL, GMI of 6.96±0.41% and TIR of 73.5±10.7%. Their TBR54, TBR70 and TAR180 were 0.11±0.15%, 1.7±1.5% and 24.8±11.0%, respectively. During the night (12AM-6AM) , TIR was 81.5±12.8%, TBR54 was 0.08±0.20%, TBR70 was 1.1±1.7% and TAR180 was 17.5±12.9%. The number of closed-loop exits was 0.8±0.9/week. Conclusion: MiniMed™ 780G system use with the Guardian™ 4 sensor involved substantial time in closed loop and favorable glycemic control that aligned with the recommended international consensus for continuous glucose monitoring metrics. Disclosure J.Shin: Employee; Medtronic. A.Arrieta: Employee; Medtronic. J.Castañeda: Employee; Medtronic. T.L.Cordero: Employee; Medtronic, Medtronic. A.S.Rhinehart: Employee; Medtronic, Stock/Shareholder; Medtronic. R.A.Vigersky: Employee; Medtronic.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
760-P: Performance of the MiniMed 780G System with the Guardian 4 Sensor—Impact on the First 1,570 Real-World Users
Date Crossref
01/06/2022
Éditeur
American Diabetes Association
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les sujets associés

Diabetes Management and ResearchArtificial Intelligence in HealthcareCardiovascular Health and Risk Factors

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.