A Deep Convolutional Gated Recurrent Unit for CT Image Reconstruction
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Computed tomography (CT) is one of the most important medical imaging technologies in use today. Most commercial CT products use a technique known as the filtered backprojection (FBP) that is fast and can produce decent image quality when an X-ray dose is high. However, the FBP is not good enough on low-dose X-ray CT imaging because the CT image reconstruction problem becomes more stochastic. A more effective reconstruction technique proposed recently and implemented in a limited number of CT commercial products is an iterative reconstruction (IR). The IR technique is based on a Bayesian formulation of the CT image reconstruction problem with an explicit model of the CT scanning, including its stochastic nature, and a prior model that incorporates our knowledge about what a good CT image should look like. However, constructing such prior knowledge is more complicated than it seems. In this article, we propose a novel neural network for CT image reconstruction. The network is based on the IR formulation and constructed with a recurrent neural network (RNN). Specifically, we transform the gated recurrent unit (GRU) into a neural network performing CT image reconstruction. We call it "GRU reconstruction." This neural network conducts concurrent dual-domain learning. Many deep learning (DL)-based methods in medical imaging are single-domain learning, but dual-domain learning performs better because it learns from both the sinogram and the image domain. In addition, we propose backpropagation through stage (BPTS) as a new RNN backpropagation algorithm. It is similar to the backpropagation through time (BPTT) of an RNN; however, it is tailored for iterative optimization. Results from extensive experiments indicate that our proposed method outperforms conventional model-based methods, single-domain DL methods, and state-of-the-art DL techniques in terms of the root mean squared error (RMSE), the peak signal-to-noise ratio (PSNR), and the structure similarity (SSIM) and in terms of visual appearance.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- A Deep Convolutional Gated Recurrent Unit for CT Image Reconstruction
- Date Crossref
- 01/12/2023
- Éditeur
- Institute of Electrical and Electronics Engineers (IEEE)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of Wisconsin–Milwaukee pays non établi dans la noticeUniversité ou école supérieure
-
University of Wisconsin-Milwaukee Department of Electrical Engineering and Computer Science pays non établi dans la noticeUniversité ou école supérieure
University of Wisconsin–Milwaukee et Department of Electrical Engineering and Computer Science — University of Wisconsin-Milwaukee.