Intraoperative aberrometry compared to preoperative Barrett True-K formula for intraocular lens power selection in eyes with prior refractive surgery
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
To compare the predictive refractive accuracy of intraoperative aberrometry (ORA) to the preoperative Barrett True-K formula in the calculation of intraocular lens (IOL) power in eyes with prior refractive surgery undergoing cataract surgery at the Loma Linda University Eye Institute, Loma Linda, California, USA. We conducted a retrospective chart review of patients with a history of post-myopic or hyperopic LASIK/PRK who underwent uncomplicated cataract surgery between October 2016 and March 2020. Pre-operative measurements were performed utilizing the Barrett True-K formula. Intraoperative aberrometry (ORA) was used for aphakic refraction and IOL power calculation during surgery. Predictive refractive accuracy of the two methods was compared based on the difference between achieved and intended target spherical equivalent. A total of 97 eyes (69 patients) were included in the study. Of these, 81 eyes (83.5%) had previous myopic LASIK/PRK and 16 eyes (16.5%) had previous hyperopic LASIK/PRK. Median (MedAE)/mean (MAE) absolute prediction errors for preoperative as compared to intraoperative methods were 0.49 D/0.58 D compared to 0.42 D/0.51 D, respectively (P = 0.001/0.002). Over all, ORA led to a statistically significant lower median and mean absolute error compared to the Barrett True-K formula in post-refractive eyes. Percentage of eyes within ± 1.00 D of intended target refraction as predicted by the preoperative versus the intraoperative method was 82.3% and 89.6%, respectively (P = 0.04). Although ORA led to a statistically significant lower median absolute error compared to the Barrett True-K formula, the two methods are clinically comparable in predictive refractive accuracy in patients with prior refractive surgery.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Intraoperative aberrometry compared to preoperative Barrett True-K formula for intraocular lens power selection in eyes with prior refractive surgery
- Date Crossref
- 05/05/2022
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Loma Linda University pays non établi dans la noticeUniversité ou école supérieure
Loma Linda University.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.