Early Outcomes of Patients Undergoing Neoaortic Valve Repair Incorporating Geometric Ring Annuloplasty
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Objectives During congenital heart surgery, the pulmonary valve and root may be placed into the systemic position, yielding a “neoaortic” valve. With the stress of systemic pressure, the pulmonary roots can dilate, creating aneurysms and/or neoaortic insufficiency (neoAI). This report analyzes the early outcomes of patients undergoing neoaortic valve repair incorporating geometric ring annuloplasty. Methods Twenty-one patients underwent intended repair at six centers and formed the study cohort. Thirteen had previous Ross procedures, five had arterial switch operations, and three Fontan physiology. Average age was 21.7 ± 12.8 years (mean ± SD), 80% were male, and 11 (55%) had symptomatic heart failure. Preoperative neoAI Grade was 3.1 ± 1.1, and annular diameter was 30.7 ± 6.5 mm. Results Valve repair was accomplished in 20/21, using geometric annuloplasty rings and leaflet plication (n = 13) and/or nodular release (n = 7). Fourteen had neoaortic aneurysm replacement (13 with root remodeling). Two underwent bicuspid valve repair. Six had pulmonary conduit changes, one insertion of an artificial Nodulus Arantius, and one resection of a subaortic membrane. Ring size averaged 21.9 ± 2.3 mm, and aortic clamp time was 171 ± 54 minutes. No operative mortality or major morbidity occurred, and postoperative hospitalization was 4.3 ± 1.4 days. At discharge, neoAI grade was 0.2 ± 0.4 ( P < .0001), and valve mean gradient was ≤20 mm Hg. At average 18.0 ± 9.1 months of follow-up, all patients were asymptomatic with stable valve function. Conclusions Neoaortic aneurysms and neoAI are occasionally seen late following Ross, arterial switch, or Fontan procedures. Neoaortic valve repair using geometric ring annuloplasty, leaflet reconstruction, and root remodeling provides a patient-specific approach with favorable early outcomes.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Early Outcomes of Patients Undergoing Neoaortic Valve Repair Incorporating Geometric Ring Annuloplasty
- Date Crossref
- 21/04/2022
- Éditeur
- SAGE Publications
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.