Aller au contenu principal
Accès ouvert déclaré 2022 article

Predictors of adverse events and early mortality after esophageal stent placement in a low resource setting: a series of 3823 patients in Kenya

4Citations signalées — pas une note de qualité
7Institutions déclarées
2Pays d’affiliation déclarés

Résumé fourni par la source

Abstract Background and study aims Dysphagia from esophageal cancer may be palliated with self-expanding metallic stents (SEMS). Controversy exists about the use of dilation before SEMS deployment. Patients and methods We performed a retrospective cohort study of patients who had SEMS placement without fluoroscopy for palliation at Tenwek Hospital in Bomet, Kenya between January 1999 and April 2019. The primary outcome was any serious adverse event (AE) (chest pain, stent migration, perforation, bleeding, or all-cause mortality) within 30 days of the procedure. Various demographic and clinical characteristics, and procedural details, were examined as risk factors. Technical success, defined as correct SEMS placement, and clinical success, defined as dysphagia score improvement without 30-day mortality, were examined. Results A total of 3823 patients underwent SEMS placement, with 2844 (74.4 %) placed in the second decade of the study. Technical and clinical success were achieved in 97.2 % and 95.5 %, respectively, with mean dysphagia scores improving from 3.4 (SD 0.6) to 0.9 (SD 1.3) post-stent placement. AEs occurred in 169 patients (4.4 %). AEs, specifically perforations, were associated with dilation to greater than 36F in the first decade. Perforation rates decreased from the first (4.1 %) to the second decade (0.2 %). Only 30% had complete 30-day follow-up data. Conclusions SEMS placement is a safe, effective method of palliating malignant dysphagia, with low rates of AEs and 30-day mortality and high rates of clinical and technical success. Dilation can facilitate placement of SEMS without fluoroscopy but should not be performed above 36F due to the risk of perforation.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Predictors of adverse events and early mortality after esophageal stent placement in a low resource setting: a series of 3823 patients in Kenya
Date Crossref
01/04/2022
Éditeur
Georg Thieme Verlag KG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude et ne compte pas comme une seconde source scientifique indépendante.

Institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Sujets associés

Esophageal and GI PathologyTracheal and airway disordersForeign Body Medical Cases

BNTIC News n’est pas le producteur de ces données. Recherche à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, ROR et la Banque mondiale, sans clé ; OpenAlex reste optionnel. Aucun service payant requis, aucune donnée externe enregistrée en base. Sources et limites.