Cross‐sectional diagnostic accuracy study of self‐testing for proteinuria during hypertensive pregnancies: The UDIP study
Rattachement africain : gb. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
OBJECTIVE: To determine the accuracy of self-testing for proteinuria during pregnancy. DESIGN: Diagnostic accuracy study. SETTING: Antenatal clinics, maternity assessment units and inpatient wards at three hospital sites. POPULATION OR SAMPLE: 345 pregnant women. METHODS: Pregnant women self-tested in-clinic for urinary protein using visually read dipsticks with samples then sent for laboratory estimation of the spot protein-creatinine ratio (PCR) (primary reference test). Secondary index tests included testing by antenatal healthcare professionals and an automated colorimetric reader. MAIN OUTCOME MEASURES: Sensitivity, specificity, negative predictive value, positive predictive value and likelihood ratios were calculated for self-testing (primary index test) along with healthcare professional and colorimetric testing compared to the primary reference test (PCR). RESULTS: 335/345 (97%) had sufficient data to be included in the analysis. Self-testing had a sensitivity of 0.71 (95% confidence interval [CI] 0.62-0.79) and a specificity of 0.89 (95% CI 0.84-0.92) compared to PCR. Sensitivity and specificity of testing by healthcare professionals and the colorimetric reader were similar: sensitivity 0.73 (95% CI 0.64-0.80) and 0.78 (95% CI 0.69-0.85), respectively; specificity 0.88 (95% CI 0.82-0.92) and 0.83 (95% CI 0.78-0.88), respectively. CONCLUSION: Pregnant women can visually read a dipstick for urinary protein with similar accuracy to antenatal healthcare professionals. Automated colorimetric testing was not significantly different, in contrast to some previous studies. Self-testing has the potential to form part of a self-monitoring regime in pregnancy.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé, mais le titre doit être comparé manuellement.
- Titre Crossref
- Cross‐sectional diagnostic accuracy study of self‐testing for proteinuria during hypertensive pregnancies: The <scp>UDIP</scp> study
- Date Crossref
- 12/05/2022
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.