High-sensitivity cardiac troponin and the diagnosis of myocardial infarction in patients with kidney impairment
Rattachement africain : gb, us, nz. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
The benefit and utility of high-sensitivity cardiac troponin (hs-cTn) in the diagnosis of myocardial infarction in patients with kidney impairment is unclear. Here, we describe implementation of hs-cTnI testing on the diagnosis, management, and outcomes of myocardial infarction in patients with and without kidney impairment. Consecutive patients with suspected acute coronary syndrome enrolled in a stepped-wedge, cluster-randomized controlled trial were included in this pre-specified secondary analysis. Kidney impairment was defined as an eGFR under 60mL/min/1.73m 2 . The index diagnosis and primary outcome of type 1 and type 4b myocardial infarction or cardiovascular death at one year were compared in patients with and without kidney impairment following implementation of hs-cTnI assay with 99th centile sex-specific diagnostic thresholds. Serum creatinine concentrations were available in 46,927 patients (mean age 61 years; 47% women), of whom 9,080 (19%) had kidney impairment. hs-cTnIs were over 99th centile in 46% and 16% of patients with and without kidney impairment. Implementation increased the diagnosis of type 1 infarction from 12.4% to 17.8%, and from 7.5% to 9.4% in patients with and without kidney impairment (both significant). Patients with kidney impairment and type 1 myocardial infarction were less likely to undergo coronary revascularization (26% versus 53%) or receive dual anti-platelets (40% versus 68%) than those without kidney impairment, and this did not change post-implementation. In patients with hs-cTnI above the 99th centile, the primary outcome occurred twice as often in those with kidney impairment compared to those without (24% versus 12%, hazard ratio 1.53, 95% confidence interval 1.31 to 1.78). Thus, hs-cTnI testing increased the identification of myocardial injury and infarction but failed to address disparities in management and outcomes between those with and without kidney impairment.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- High-sensitivity cardiac troponin and the diagnosis of myocardial infarction in patients with kidney impairment
- Date Crossref
- 01/07/2022
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.