90 Annular size and interaction with trans-catheter aortic valves for the treatment of severe bicuspid aortic valve stenosis: insights from the beat registry
Rattachement africain : it, fr, de, il, dk, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Aims Transcatheter aortic valve replacement (TAVR) is safe and feasible in patients with bicuspid aortic valve (BAV), but whether annular size may influence TAVR results in BAV patients remains unclear. We aimed at evaluating the impact of aortic annular size on procedural and clinical outcomes of BAV patients undergoing TAVR, as well as potential interactions between annular dimension and trans-catheter heart valve (THV) type [balloon-expandable (BEV) vs. self-expanding (SEV)]. Methods and results BEAT is a multicentre registry of consecutive BAV stenosis undergoing TAVR. For this sub-study patients were classified according to annular dimension in small-annulus (area < 400 mm2 or perimeter <72 mm), medium-annulus (area ≥ 400 and < 575 mm2, perimeter ≥72 mm and< 85 mm), large-annulus (area ≥575 mm2 or perimeter ≥85 mm). Primary endpoint was Valve Academic Research Consortium-2 (VARC-2) device success. 45(15.5%) patients had small, 132(45.3%) medium, and 114(39.2%) large annuli. Compared with other groups, patients with large annuli were more frequently male, at younger age, had higher body mass index, larger aortic valve area, higher rate of moderate-severe calcification, lower mean trans-aortic valve gradient and lower left ventricular ejection fraction. In large-annuli SEVs were associated with a lower VARC-2 device success (75.9% vs. 90.6%, P = 0.049) driven by a higher rate of paravalvular valvular leak (PVL) compared to BEVs (20.7% vs. 1.2%, P < 0.001). However, no differences in clinical outcomes were observed according to annular size nor THV type. Conclusions TAVR in BAV patients is feasible irrespective of annular size. However in patients with large aortic annulus SEVs were associated with a significantly higher rate of PVLs compared to BEVs.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- 90 Annular size and interaction with trans-catheter aortic valves for the treatment of severe bicuspid aortic valve stenosis: insights from the beat registry
- Date Crossref
- 01/12/2021
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.