Aller au contenu principal
Accès ouvert déclaré 2021 article

703 Koch’s triangle voltage mapping for cryoablation of slow pathway in children: preliminary data of a novel high density technique

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Aims Different authors have described three-dimensional (3D) voltage mapping of the Koch’s triangle (KT) in order to find low-voltage bridges (LVBs) as targets for a successful transcatheter ablation (TCA) of the slow pathway (SP) in children. Recently, the advisor high density (HD) Grid™ mapping catheter was introduced as new multipolar catheter for HD mapping. The aim of the study was to describe our preliminary experience with the use of HD Grid™ catheter in LVB and electrophysiologically guided cryoablation of SP in children. Methods and results Twenty-one children (mean age 13 ± 3 years) with atrioventricular nodal re-entrant tachycardia (AVNRT) underwent cryoablation of SP guided by voltage HD mapping of the KT using HD Grid™ catheter. In order to better highlight the differences with conventional mapping, point collection was performed in each patient with this new multipolar catheter and with a quadripolar catheter. The conventional mapping collected 871 ± 262 points and used 211 ± 80 points in 887 ± 275 s, whereas HD mapping collected 7468 ± 2947 points, using 604 ± 165 points in 513 ± 181 s (P < 0.001). Moreover, the LVB area mapped with HD Grid™ was about one-half smaller and clearly delineated. Cryoablation acute success rate was 100%. Overall median fluoroscopy exposure was 0.08 (0.01–5.42) µGy/m2, with a median fluoroscopy time of 0.1 (0.0–0.6) min. During the follow-up (4.8 ± 3.7 months), there were no recurrences. No complications occurred. Conclusions Our preliminary experience shows that HD mapping is faster and offers higher spatial resolution and definition. Procedural time can be reduced maintaining the TCA safe, with reduced fluoroscopy use, and successful.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
703 Koch’s triangle voltage mapping for cryoablation of slow pathway in children: preliminary data of a novel high density technique
Date Crossref
01/12/2021
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Arrhythmias and TreatmentsCardiovascular Syncope and Autonomic DisordersAtrial Fibrillation Management and Outcomes

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.